Renishaw plc RMP60 用户手册

下载
页码 42
21
RMP60/shank mounting
RMP60/shank mounting
Note :
1
. DURING ADJUSTMENT CARE SHOULD
BE TAKEN NOT TO ROTATE THE RMP60
RELATIVE TO THE SHANK.
2. IF A RMP60/SHANK UNIT IS ACCIDENTALLY
DROPPED, IT SHOULD BE CHECKED FOR
ON-CENTRE POSITION.
3. DO NOT HIT OR TAP THE PROBE TO
ACHIEVE ON-CENTRE ADJUSTMENT.
Stage 1    RMP60/shank mounting
If the RMP60 does not have a shank switch,
please proceed from note 3.
1.
Remove plug from rear of RMP60 using pliars.
2.
Place bobbin into shank.
3.
Fully slacken four screws A.
4.
Grease two screws B, and fit into shank.
5.
Fit RMP60 onto the shank, and visually
position centrally.
6.
Tighten screws B to 6-8 Nm (4.4- 5.9 lb.ft)
(Partially tighten screws to 2 - 3 Nm
(1.47 - 2.2 lbf.ft), if RMP60 is to be on-centre
adjusted).
7.
The RMP60 assembly is ready for use.
B
A
Bobbin
Switch