Renishaw plc RMP60Q 用户手册
RMP60 installation guide
7.4
Fault-finding
Symptom
Cause
Action
RMI or RMI-Q error LED
lit during probing cycle.
lit during probing cycle.
Probe not switched on or probe
timed out.
timed out.
Change setting. Review turn off
method.
method.
Probe out of range.
Check position of RMI or RMI-Q
see operating envelope.
see operating envelope.
RMI or RMI-Q low
battery LED lit.
battery LED lit.
Low batteries.
Change batteries soon.
Reduced range.
Local radio interference.
Identify and remove.
Probe fails to switch off.
Incorrect switch off method
configured.
configured.
Check configuration and alter as
required.
required.
No RMI or RMI-Q 'start/stop'
signal (radio on mode only).
signal (radio on mode only).
Check RMI or RMI-Q for green
start LED.
start LED.
Probe in timeout mode and
placed in tool magazine and is
being triggered by movement.
placed in tool magazine and is
being triggered by movement.
Use shorter timeout setting or use
different switch off mode.
different switch off mode.
Malfunctioning shank switch
(shank switch mode only).
(shank switch mode only).
Check switch operation.
Incorrect spin speed (spin switch
on only).
on only).
Check spin speed.
Level start used for M code on/off
when the probe is set to radio on/
timeout off.
when the probe is set to radio on/
timeout off.
Change to a pulsed M code or
change the probe to radio on/off.
change the probe to radio on/off.
Probe goes into Trigger
Logic™ configuration
mode and cannot be
reset.
Logic™ configuration
mode and cannot be
reset.
Probe was triggered when
batteries were inserted.
batteries were inserted.
Do not touch the stylus or stylus
mounting face during battery
insertion.
mounting face during battery
insertion.