RMP60 installation guide
7.4
Fault-finding
Symptom
Cause
Action
RMI or RMI-Q error LED 
lit during probing cycle.
Probe not switched on or probe 
timed out.
Change setting. Review turn off 
method.
Probe out of range.
Check position of RMI or RMI-Q 
see operating envelope.
RMI or RMI-Q low 
battery LED lit. 
Low batteries.
Change batteries soon.
Reduced range. 
Local radio interference.
Identify and remove.
Probe fails to switch off.
Incorrect switch off method 
configured.
Check configuration and alter as 
required.
No RMI or RMI-Q 'start/stop' 
signal (radio on mode only).
Check RMI or RMI-Q for green 
start LED.
Probe in timeout mode and 
placed in tool magazine and is 
being triggered by movement.
Use shorter timeout setting or use 
different switch off mode.
Malfunctioning shank switch 
(shank switch mode only).
Check switch operation.
Incorrect spin speed (spin switch 
on only).
Check spin speed.
Level start used for M code on/off 
when the probe is set to radio on/
timeout off.
Change to a pulsed M code or 
change the probe to radio on/off.
Probe goes into Trigger 
Logic™ configuration 
mode and cannot be 
reset.
Probe was triggered when 
batteries were inserted.
Do not touch the stylus or stylus 
mounting face during battery 
insertion.