Renishaw plc RMP60V2 用户手册

下载
页码 47
26
Battery life expectancy
Typical battery life
Using standard alkaline batteries at 5 % usage,
typically the probe will continue to operate for
approximately 1 week after a low battery
warning is first indicated.
Replace the batteries as soon as is practicable.
Battery life expectancy
Two
AA type
STAND-BY
LIFE
(days - typical)
STAND-BY
LIFE
(days - typical)
5% USAGE
72 min/day
(days - typical)
CONTINUOUS
USE
Alkaline
  650
100
 130
65
  140
5% USAGE
72 min/day
(days - typical)
After batteries are inserted into the RMP60,
the LEDs will indicate the current settings.
In order to achieve the stated radio turn-on life
(stand-by or 5% usage), the RMP60 must
be in range of its powered partner RMI.
SHANK/SPIN TURN  ON
RADIO TURN  ON
(hours - typical)
BATTERY
LTC
 1,300
 200
  260
130
   280
LTC  (Lithium Thionyl Chloride)