Chungear Industrial Co Ltd CE10010 用户手册
LEARNING PROCESS
1. This unit finished learning process inside manufactory, if replace transmitter or receiver, user
need to redo learning process before using this unit.
2. Open battery cover (with battery, DC9V 1pcs, installed) and use a ball pen to set Code switch
up or down (Fig. 1). Then turn ceiling fan power on, press transmitter “FAN OFF” key over
5seconds, down light will be flash twice, which indicate that learning process finished. Learning
effect distance is same with remote’s. Please note that must press the “FAN OFF” key within
30sensonds after power on. If just replace batteries, no need to re-learn.
3. Please note that the transmitter can learn in multiple receiver, when doing learning process
please make sure not learn in other receiver. Suggest to separate power switches of fans in 2
meter range.
LIGHT FUNCTION SELECT SWITCH
1. If installed energy light onto ceiling fan down light, please slide the “down light function select
switch” to “O” position (Fig. 2). If installed tungsten light onto ceiling fan, please slide the “down
light function select switch” to “D” position.
FUNCTIONS OF TRANSMITTER
LIGHT : ON/OFF- Press and release immediately to turn on or off
the light.
DIMMER-Press and hold to dim or brighten light
to the desired level and release.
(Tungsten only and down light function select
switch” to “D” position.)
FAN OFF : Turn off the ceiling fan.
HI :Turn on the fan at high speed
MED :Turn on the fan at medium speed
MODEL:TR125B
LOW : Turn on the fan at low speed
REVERSE :
Press and release immediately to set
fan wind direction up or down.
TRANSMITTER
Installation of
Transmitter Wall
Mount Holder with
two screws.
CODE SWITCH
Fig. 1
DOWN LIGHT FUNCTION
SELECT SWITCH
Fig. 2