8.4 On-air 
subscription 
CT-DECT devices standard of group 1
 
In the following by way of an example the subscription of the max. four CT-DECT Multi Standard (PP) 
of group 1 to the CT-DECT Case is described.  
 
8.4.1  On-air subscription of the first CT-DECT Multi Standard (PP) of group 1 
a.  Ensure that the CT-DECT Multi Standard (PP) switched off and the CT-DECT Case is switched on. 
b.  Prepare the first CT-DECT Multi Standard (PP) for the operation, leave it however switched off. Con-
sider the special CeoTronics operating instructions of the CT-DECT Multi Standard (PP). 
c.  At the CT-DECT Case press the subscription button »1« (Fig. 3/e) and keep it min. 5 sec. pressed. 
Then release the subscription button. Immediately carry out step »d«, otherwise a »Time Out« may 
occur. 
d.  At the first CT-DECT Multi Standard (PP) press the subscription button and keep the subscription 
button pressed. While you keep the subscription button pressed switch on the CT-DECT Multi Stan-
dard (PP) and after switching on keep the subscription button still pressed for at least 5 seconds until 
a descending 5-tone sequence is audible in the communication set. Then release the subscription 
button. 
The subscription is started and in the communication set a short high beep tone is audible periodi-
cally every 2 seconds. An increasing 5-tone sequence - which repeats itself every 4 seconds - sig-
nalize that the subscription has been successful completed. 
If no successful subscription was achieved after maximally 2 minutes, then this is signalized by a to-
ne sequence of 4 short deep tones, which repeats itself every 4 seconds.  
  Then switch off the CT-DECT Multi Standard (PP) and restart the subscription procedure. 
e.  After the successful on-air subscription switch off again the subscribed first CT-DECT Multi 
Standard (PP).  
The subscription procedure of the other three CT-DECT Multi Standard (PP) is the same like for 
the first device.