Lelux Electronics Ltd 625TX 用户手册

下载
页码 1
a.In standby mode, using a pen to press LEARN button once will 
sound beep, press again will sound other one, press the button 
select sound for you want, then keep press LEARN button 2 
seconds will hear a beep tone then release the button, the unit now 
ready to receive learn code signal from transmitter.
b.Trigger wireless garage door open detector sensor (pull up and put 
down detection rob will trigger it ), you will hear a long beep tone 
confirming that the progamming of learn code was done 
successfully (When programming LEARN  code was unsuccessful, 
you will hear four short beep tones). Please program again.
Learn ID code to T016S,T015S auto dialer main unit:
a. Open terminal compartment of main unit. ( Fig.4)
b. Press and hold LEARN button 2 seconds you will hear one beep 
tone then un-pressed the button, the unit now ready to receive 
learn code signal from transmitter.
c. Trigger wireless garage door open detector sensor (pull up and put 
down detection rob will trigger it ).
d. You will hear a long beep tone confirming that the programming of
     learn code was done successfully (When programming LEARN  
code was unsuccessful, you will hear four short beep tones). 
Please program again.
Learn ID code to T018S auto dialer main unit:(Fig.5)
a. Enter the pass number followed by[PROG]button three times.
b. The " LEARN " icon will flash on the LCD.
c. Press[ARM/DISARM]to confirm, the system will turn into 
learning ID code setup and zone 1 icon flash.
d. Press the[*/UP]and[#/DOWN]buttons to select you want 
setup zone, when LCD display “NO ID CODE” is meaning the zone 
is disengaged, you can learn new sensor id code for this zone; 
when LCD display “FULL” is meaning the zone had ID code,you
    can select other zone or press[DEL./PAUSE]button to delete 
( Fig. 4 )
( Fig.5)
2
    original id code then relearn new id code for this zone. 
e. Press[ARM/DISARM]to confirm.
f.  Trigger wireless garage door open detector sensor (pull up and 
put down detection rob will trigger it ).(Fig.5)
g. you will hear a long beep tone confirm learn code successfully and 
LCD will display “FULL” for  zone 1 ~ zone 8 or  “1 ID CODE IN” 
for zone 9.
h. press[PROG]button seven times to exit the setup mode.
Learn ID code to 526L wireless outdoor siren with flash light:
a. Open battery compartment cover. ( Fig.6)
b. use a pen to press and hold LEARN button for 2 seconds, a beep 
tone will sound , then release the button, the unit now ready to 
receive LEARN ID code signal from transmitter.
c. Trigger wireless garage door open detector sensor (pull up and 
put down detection rob will trigger it )
d. you will hear a long beep tone confirming that the programming 
   of learn code was done successfully (When programming LEARN  
code was unsuccessful, you will hear four short beep tones). 
Please program again.
4. TO TEST TRANSMITION RANGE
    After select a location, you should test the sensor transmitting 
range before mount it permanently, turn power switch to ON of 
625RX main unit or turn the CHIME switch to ON of T015S main 
unit or press HOME button of T018S, after 60 seconds,  then 
Trigger wireless garage door open detector sensor (pull up and 
put down detection rob will trigger it ), you will hear the main unit 
sounds “DING DONG” chime or alert sound if signal is received 
successfully, if not , change location is required.
5.Installation for up/down type garage door:
a.Before you install the sensor onto the garage door, make sure 
the garage door is closed, the sensor assembly should be 
mounted on one of the vertical supports of your garage door 
near the bottom. When the door is closed, the detection rod 
should be retracted. When the door is open, the detection rod 
will be extended.(fig.7)
( Fig.6)
3
Size:90X175mm
p/n:610-62501-000R
white paper print black words
FEATURES
•  Detect garage door open out put wireless trigger signal
•  Garage door sensor 3V lithium battery (CR2032) operation 
(included)
•  IP44 Water and weather resistant 
•  External trigger input terminal compatible wired magnetic sensor    
for normal door
•  Battery low indicator LED 
•  Wireless RF transmission distance about 30~40 meters (open 
space)
DESCRIPTION OF COMPONENTS
1. Built-in detect sensor rod
2. Built-in detect sensor rod lock
3. External sensor terminal
4. Battery cover
5. Built-in sensor/external 
    sensor select switch
INSTALLATION
1.Remove the screw of garage door sensor battery cover, and open 
the battery door.(Fig.1) 
2.install a 3V lithium battery (CR2032 or equate type) for garage
   door sensor,  compartment make sure install with correct  polarity. (Fig.2)
3. LEARN ID CODE TO MAIN UNIT
    The wireless garage door open detector sensor compatible model: 
625RX, T015S, T016S, T018S, 526L, must learn code to main 
unit then use, the learning code can only be operated during 
disarm mode. Follow these steps:
Learn ID code to 625RX  wireless alert receiver unit:( Fig.3)
 
LOCK
UNLOCK
2
5
1
3
4
(Fig.2)
(Fig.1)
LEARN
1
( Fig.3)
b.You can mount the sensor onto your garage door with 
double-sided foam tape if the surface of your garage door is 
smooth and clean enough to provide a good adhesive surface, 
such surface can usually be found on a metal garage door. 
Please ensure the surface is smooth and clean. the bottom of 
the sensor should be 15mm above the ground.(fig.8) 
c.For wooden garage doors, it is recommended to mount the 
sensor with screws onto the garage door with screws provided. 
(fig.9)
Note: 
   When the garage door is opening/closing, make sure the sensor 
does not interfere with the safety reversing sensor or safety beam 
sensor supplied with your existing garage door opener.
6.Installation for external magnetic sensor :
a.Remove the screw from battery compartment cover.
b.Connect the external magnetic sensor (included) to 
terminal.(Fig.10)
c.Turn sensor select switch to EXT.(external)
d.Replace the battery cover and screw.
    e.Pull up the detection rob to top and turn lock switch to 
LOCK.(fig.11) 
    f.Choose a suitable location, use double-sided foam tape or 
screws to mount the unit.
   g.Mount the magnetic wired piece to the door frame and another 
single piece to the door by using the double-side tapes (included) 
(Fig.9)
LOCK
LOCK
UNLOCK
(Fig.8)
LOCK
LOCK
UNLOCK
15mm
(Fig.10)
(Fig.11)
LOCK
LOCK
UNLOCK
LOCK
LOCK
UNLOCK
4
(Fig.7)
LOCK
LOCK
UNLOCK
Door closed
LOCK
LOCK
UNLOCK
Door open
  and aligned the 2 sensor pieces to be flushed and “   ” facing “   ”  
at no more than 15mm. (fig.12.13.14) 
h.If you connect more than one sensor to unit,connect them in 
series as shown below.(Fig.15)
i.Connect the sensor switch on door to the main terminal post 
using the wire you just cut. (There is no polarity need to be 
taken care of, any terminal will be fine, as long as the wires from 
a loop) 
OPERATION
After  60  seconds  installed  3V  battery,  the  unit  will  into  standby 
mode. Once the door/window opened will output wireless radio signal 
and LED flash.
  
BATTERY LOW INDICATOR
     When garage door sensor battery goes low, sensor unit battery 
low led will flash once every second .
FCC COMPLIANCE STATEMENT
     This equipment has been tested and found to comply with the limits 
for a Class B digital device,  pursuant  to  Part  15  of  the  FCC  Rules. 
These  limits  are  designed  to  provide reasonable  protection  against 
harmful  interference  in  a  residential  installation.  This equipment 
generates, uses, and can radiate radio frequency energy and, if not
LOCK
LOCK
UNLOCK
(Fig.14)
(Fig.15)
5
1
2
3
Tape
610-62501-000R
garage door
LOCK
LOCK
UNLOCK
about 600mm
garage door
LOCK
LOCK
UNLOCK
about 600mm
(Fig.12)
(Fig.13)
OWNER'S MANUAL
Garage Open Alert
MODEL:625T
LOCK
LOCK
UNLOCK
installed and  used  in  accordance  with  the  instrucitons, may  cause 
harmful  interference  to  radio communications.  However,  there  is  no 
gurantee  that  interference  will  not  occur  in  a particular installation.
      If this equipment does cuase harmful interference to radio or 
television reception, which can be determined by turning the 
equipment of f and on, the user is envouraged to try to  correct the 
interference by one or more the of the following measures: 
-  Reorient or relocate the receiving antenna.
-  Increase the separation between the equipment and the receiver.
-  Connect  the  equipment  into  an  outlet  on  a  circuit  different  from 
that  to  which  the  receiver is connected. 
-  Consult the dealer or an experienced technician for help.
     This device complies with Part 15 of the FCC Rules and with 
RSS-210 of Industry  Canada. Operation is subject to the following two 
conditions:
1)  This device may not cause harmful interference, and
2)  This device must accept any interference received, including 
interference that may cause undesired operation. 
WARNING: Changes or modifications not expressly approved by Lelux 
could void the user’s authority to operate the equipment.      
6