Koden Electronics Co. Ltd RB715L 用户手册
41
OFF-C
→
Up/Down & Left/Right
→
ENT ---------------- Conduct Off Center to exit the adjustment state.
Note: VRM2 and EBL2 do not follow the OFF-C function while floating.
The function operates on PPI screen only.
(b) To cancel the setting
OFF-C
---------------------------------------------------The "OFF-C" display at the upper right disappears and function
returns to the ordinary state from the Off Center state.
5.4.15 Setting of the SLEEP function(SLEEP)
This function sends a 30-second-transmissions during pre-fixed hours. After a
transmission, a power-saving mode is entered with the screen in ST'BY state (the scanner-OFF
state) and the LCD backlight turned off. This action is repeatedly executed.
Usage example, set a guard zone and have the warning signal automatically confirmed every
prefixed period.
Press the "SLEEP" key. Every pressing the key, "SLEEP" function will be set as 5-minutes,
10-minutes, 15-minutes, or off.
When a transmission is conducted after setting a SLEEP mode, a ST'BY state is entered
and the backlight turns off after a 30-second-transmission. (Power-saving mode). Two minutes
before the fixed time the backlight turns on and the 2-minute timer starts. Then, at the fixed
time another 30-second-transmission begins. This series of actions are repeated. If any one key
is pressed during the course of this action, the SLEEP function will be canceled.
Note: Refer to "5.5.2.4 Setting of the SLEEP function(SLEEP)".
(1) Setting procedure
SLEEP
→
(Select 5min.)
→
ENT
→
POWER ---
→
30-second-transmission every 5 min.
µ
transmission ON
SLEEP
→
(Select 10min.)
→
ENT
→
POWER --
→
30-second-transmission every 10 min.
µ
transmission ON
SLEEP
→
(Select 15min.)
→
ENT
→
POWER --
→
30-second-transmission every 15 min.
µ
transmission ON
SLEEP
→
(Select OFF) --------------------------------------- SLEEP function is turned OFF
Setting completed
5.4.16 Tuning adjustment (TUNE)
(1) When the "TUNE" key is pressed, the TUNE display on the upper-right side of the
screen will be reversed as
35
and the adjustable state will be entered.
(2) When the control knob is turned, the figure will be shifted within a range of 0 and