OPTI DS1000B-RM 产品宣传页

下载
页码 2
CS730B
* Zero transfer time (online)
* Smart fan speed control
* Saves more power and minimizes noise
* 4 hours recharge time
* Cold start (DC power on)
* EPO port ready: emergency power off switch
* SNMP card slot available
* Hot swappable / replaceable battery: continuous
  operation even when battery is being replaced
* Extended battery pack (optional)
* RS232 and USB port
* Full version of OPTI-SAFE software
34.
DS1000B-RM/ DS1500B-RM/ DS2000B-RM/ DS3000B-RM
* DS1000B-RM
Durable Series
Specifications
For data centers and mission
critical systems
Model Name
DS1000B-RM
DS1500B-RM
DS2000B-RM
DS3000B-RM
Topology
On-battery Output Waveform
Maximum Capacity
1000VA / 700W
1500VA / 1050W
2000VA / 1400W
3000VA / 2100W
INPUT
Nominal Input Voltage
Input Voltage Regulation
Nominal Input Frequency
Input PFC
Input Short Protection
OUTPUT
Nominal Output Voltage
Output Voltage Regulation
Output T.H.D
High Efficiency Mode (AC to AC)
Crest Factor
Start on Battery
Auto Restart
Number of Outlets
PROTECTION
Data Line Surge Protection
Surge Energy Rating
Overload Protection
Short Circuit Protection
BATTERY
User Replaceable Battery
DC36V / 12V 7.2Ah × 3 DC36V / 12V 34W × 3 DC72V / 12V 7.2Ah × 6 DC72V / 12V 34W × 6
Typical Backup Time (Full / Half load)*
6 / 18 min
5 / 15 min
6 / 18 min
5 / 15 min
Recharge Time to 90% (Typical)
BP1000-RM
BP1500-RM
BP2000-RM
BP3000-RM
12V 7.2Ah × 6
12V 34W × 6
12V 7.2Ah × 12
12V 34W × 12
Front Panel LEDs
Audible Alarms
COMMUNICATION INTERFACE
Communication Port
SNMP Manageable
ENVIRONMENTAL
Operation Temperature
Storage Temperature
Relative Humidity
Audible Noise
PHYSICAL
Dimensions (Physical / Packing)      (in)
(LxWxH)                                        (mm)
Weight (Net / Gross)                       (lbs)
                                                         (kg)
40.1 / 47.4
18.2 / 21.5
40.6 / 47.8
18.4 / 21.7
69.7 / 74.5
31.6 / 33.8
71.6 / 78.7
32.5 / 35.7
Battery Pack Dimensions                 (in)
(LxWxH)                                        (mm)
Battery Pack (Net / Gross)              (lbs)
                                                         (kg)
CONFORMANCE
Approvals
Specifications are subject to change without notices.
** The external battery pack is optional. Battery pack needs to be connected to UPS before connecting any load and turning on the UPS.
# The model with optional USB port provides both RS232 and USB connectivity, but only one connectivity can be used at the same time.
 3% T.H.D at Linear Load
92%
3 : 1
ADVANCED WARNINGS / DIAGNOSTICS
UL / cUL(1X0V) ; CE , A-Tick , C-Tick , GOST-R(2X0V)
48.7 / 53.1
22 / 24
94 / 101.7
42.5 / 46
Single Phase (2W+G)
6 Battery backup (US)
4 Battery backup (IEC)
4 Battery backup (US)
5 Battery backup (IEC320 10A×4, IEC320 16A×1
1)
RJ11 / RJ45
Yes
Yes
Rated Voltage +/-2%
16.9×16.7×3.3 / 21.7×21.5×8.1
428×425×84 / 552×546×206
25×16.9×3.3 / 29.5×21.7×8.7
635×428×84 / 750×550×220
16.7×16.9×3.3 / 21.5×21.7×8.1
425×428×84 / 546×552×206
25×16.9×3.3 / 29.5×21.7×8.7
635×428×84 / 750×550×220
0~40°C / 32~104°F
-20~60°C / -4~140°F
0~95% humidity, non-condensing
< 40 dBA (at 1 meter from surface of unit)
AC mode / On line / On battery / Bypass / Fault / Overload and 15 UPS Parameters
Battery mode / UPS faults / Overload
RS232 and USB
#
Yes
 125% Load for 1 minutes 150% of 10 seconds(on line, 130% Load for 10 seconds >130%
UPS output cut offf immediateiy
 4 Hours
80-144Vac(100/110/120Vac) or 160-276Vac(220/230/240Vac)
50Hz / 60Hz Auto Sensing
Extended Battery Pack (Optional)**
True On-Line, Double Conversion
Sine Wave
100/110/120Vac or 220/230/240Vac
 0.97@Full load
Circuit Breaker
100/110/120/127Vac or 220/230/240Vac (selectable)
125J(100/110/120Vac) ; 280J(220/230/240Vac)
* Typical backup time depends on power consumption of equipment attached and on UPS battery capacity. Values here are for reference only.
Line Interactive
UPS Series
On-Line UPS
Series
Stabilizer
 Series
Networking
Series
Inverter Series Surge Series  Power Storage
 Series
Standby UPS
Series
Maximum Capacity