To remove a battery pack, push the locking tab down and pull the battery out from the charging pocket with a hinging motion.
Analyzing The Battery Pack
To analyze a battery, insert it into charging pocket #4  and press the Analyze button.  The Analyze LED will flash during the 
analyzing cycle.  This starts an automatic process in which batteries are completely discharged and then recharged to full 
capacity in 10 hours.  Upon completion, the battery capacity status is displayed on the LED display.  The Analyze cycle resets 
and calibrates battery data so that the user gets longer, more consistent performance from the batteries.  
Because the Dolphin QuadCharger is accumulating battery pack information during the entire Analyze cycle, it is important not 
to remove the battery until the cycle has been completed and the Condition LED is no longer flashing.  The chart below describes 
the Status LEDs during the Condition and Calibrate cycle:
Storing Batteries
To maintain top performance from batteries, follow the guidelines below when storing them:
Avoid storing batteries outside of the specified temperature range of -4 to 104° F (-20 to 40°C) or in extremely high humidity.
For prolonged storage, do not keep batteries stored in a charger that is connected to a power source.  
Status LED
Description
Green
Charging is complete and 
battery is ready for service.  
Orange
Battery is being charged at a 
maximum charge rate
Red
Error was encountered during 
charge cycle
                              Status of LEDs during Charging Cycle
Status LED
Description
Solid Green
Cycle is complete.  
Flashing Orange
Battery is being analyzed
Solid Red
Error was encountered during 
charge cycle
          Status of LEDs during Analyze Cycle