Xmark Corporation APC 用户手册

下载
页码 16
Compact eLink Reader 
 
 
981-000037-000 
eXI Wireless Systems 
July 2003 
  
Revision 
1.0 
 
 
1.1.  Initializing the Compact eLink Reader System 
The Compact eLink Reader System may be installed without a Wireless Keypad.  
In this simplest of configurations, a switch may be connected at the 10 pin I/0 
plug between pin 5 and signal ground to bypass alarms.  The remainder of this 
manual assumes the configuration includes one or more Wireless Keypads.  “Con-
troller” and “Reader” will be used hereafter in reference in place of “Compact 
eLink Reader”. 
 
The Controller is powered from a 12Vdc source.  This may be a UL/CSA listed 
AC/DC adapter at 300 maDC minimum.  The supply may be wired through the 10 
pin I/O connector or the DC 2.l mm Power jack.  If the 2.1 mm power jack is 
used, the center pin is positive. 
When a Wireless Keypad is included in the installation it must be configured to 
communicate with the controller.  The following procedure initiates the keypad 
for the reader: 
 
1.  Plug in the 12 VDC power source. 
2.  Preset the rotary switch SW1 on the controller to match the keypad (posi-
tion 0-7).  
3.  Type Master password (9876- Factory Default) on keypad and then 
press the ‘Enter’ key. (The green bypass led should blink on the keypad) 
4.  Type number (1) on the keypad. 
5.  Press ‘Enter’ key. 
6.  Press ‘Clear’ key. (Hear a short beep) 
7.  Type Master password (9876 - Factory Default) on keypad and then 
press the ‘Enter key’. 
8.  Enter number (1) on keypad and press the ‘Enter’ key. 
9.  Type in a 4-digit code ”XXXX” and press the ‘Enter’ key.  (Hear 2 short 
beeps)                   
 
The controller should now be configured to communicate with the keypad.   
To confirm, retype the 4-digit code on keypad and press ‘Enter’ key.   
You should hear an alarm accompanied by alternating red and the yellow LEDs.   
 
If no alarm, then repeat the configuration process, ensuring that the keys are 
pressed properly each time you enter a number.  
 
After the controller has been configured, each time that you enter the 4-digit 
code, a low tone alarm should go off and you should see alternating red and yel-
low LEDs on the controller.