Balluff Inc BISC6XX 用户手册

下载
页码 43
23
23
english
Sub-
Meaning
Function Description
address
01
Hex
Error code (continued)
02
Hex
Read error.
03
Hex
Data carrier was removed from the active zone of the read/write
head while it was being read.
04
Hex
Write error.
05
Hex
Data carrier was removed from the active zone of the read/write
head while it was being written.
07
Hex
AV bit is set but the command designator is missing or invalid.
                  or
Number of bytes is 00
Hex
.
09
Hex
Cable break to select read/write head, or head not connected.
0C
Hex
The EEPROM cannot be read/programmed.
0D
Hex
Faulty communication with the Data carrier.
Note: Verify installation criteria or distance between data carrier
and read/write head.
0E
Hex
The CRC of the read data does not coincide with the CRC of
the Data carrier.
0F
Hex
Contents of the 1st and 2nd bit header (1st and last bytes) of
the output buffers are not identical (2nd bit header must be
served).
11
Hex
Invoking a function that is not possible, since the processor is in
“compatible with BIS C-6_2” mode.
12
Hex
Copying is not possible, since a command is already started
on Head 2.
or:
Data
Data  which was read from the Data carrier.
(continued on next  )
Function Description
Input buffer, configuration and explanation
Description of
Input Buffer
(continued)
Please note the
basic procedure on
 14 and 29...35
and the examples on
pages 
 36...53.
C60_2-019_818217_0806-e.p65
24
english
24
Function Description
Input buffer, configuration and explanation
Description of
Input Buffer
(continued)
Sub-
Meaning
Function Description
address
02
Hex
Data
Data  which was read from the Data carrier.
...
Data
Data  which was read from the Data carrier.
Last byte
2nd Bit header
The data are valid if the 1st and 2nd bit headers are in
agreement.
or
Data
Data  which was read from the Data carrier.
Please note the
basic procedure on
 14 and 29...35
and the examples on
pages 
 36...53.