Honeywell International Inc. 51598SL 用户手册

下载
页码 80
RCA902A
 
69-2157EFS—04
Motion Detector Walk Test
IMPORTANT:
 Before commencing walk test ensure the LED indicator behind the 
detector lens is not flashing continuously. If it is wait until the detector has completed 
its warm-up cycle and the flashing stops.
Configure the detector for walk testing according to the selected Day or Night operat-
ing mode as follows:
1)  Set the TIME control fully counter-clockwise to its minimum setting.
2)  If the detector is set to DAY operation (for use with a chime), adjust the DUSK 
control fully counter-clockwise to its minimum setting. If the detector is set to 
NIGHT operation (for use with lighting) adjust the DUSK control fully clockwise to 
its maximum setting.
M27297
TIME
CONTROL
DUSK CONTROL 
SETTING FOR 
DAY OPERATION
DUSK CONTROL
SETTING FOR 
NIGHT OPERATION
Fig. 5
69-2157EFS_B.indd   9
5/14/2008   9:35:45 AM