Power OUTs 
Page 15 
Power OUTs 
It is possible manage 2 digital outputs NC (Normally Close) or NO (Normally 
Open) 
Usually the OUT1 is dedicated to the Door Electrolock 
Usually the OUT2 is dedicated to the Busy  lamp. 
However the Outputs can be also used as general purpose outputs 
Mode NC/NO select by JP 3 and JP4 
JP3 Î 1-2 OUT 1 NO (default) 
   
2-3 OUT 1 NC 
JP5 Î 1-2 OUT 2 NO (default) 
   
2-3 OUT 2 NC 
 
Figure 10: JP3 and JP5 position 
 
Internally, the output lines are provided with Power Mosfet that can drive to 
ground: 
   1,2A 
30V 
continuous 
   5A 
30V 
(0,5 
sec) 
peak 
current for inductive loads 
JP3 1-2 
JP5 1-2 