RFID Guidelines
Creating Basic RFID Label Formats
RFID Label Format 3—Write a 96-bit Tag in ASCII
This label format is different in what shows on the front panel. The front panel always displays 
RFID data in hexadecimal.
Resulting Label
Programmed to Transponder
00 rfid data
Front Panel Display (toggles between these two)
Line 
Number
Type This ZPL Code
Function of ZPL Code
1
^XA
Indicates start of label format.
2
^RS4
Sets tag type to EPC Class 1 96-bit.
3
^FO50,50
^A0N,65
^FDSimple write example
^FS
Prints “Simple write example” on the label at location 
50,50.
4
^RFW,A
^FD00 rfid data
^FS
W,A = write ASCII
Writes the 12 bytes of data (96 bits) to the tag. The 
data written is: 00 rfid data
5
^XZ
Indicates end of label format.
Simple write example
 RFID TAG DATA
 3030207266696420
 RFID TAG DATA
 64617461