Troubleshooting
Printer Diagnostics
Printer Diagnostics
Self tests give information about the condition of the printer. The most commonly used are the 
Power-On and the CANCEL self tests.
Power-On Self Test
The Power-On Self Test (POST) is performed automatically each time the printer is turned on. 
During either test sequence, the front panel LEDs light up and the LCD monitors the progress 
of the POST. If the printer fails any of these tests, 
FAILED
 shows on the LCD. If this occurs, 
notify an authorized Zebra reseller.
Additional Printer Self Tests
These self tests produce sample printouts and provide specific information that help determine 
the operating conditions for the printer.
Each self test is enabled by pressing a specific front panel key or combination of keys while 
turning the power On (I). Keep the key(s) depressed until the DATA light turns off. When the 
POST is complete, the selected self test starts automatically.
Caution • Be sure that the print width is set to match the label width you are using before 
running any self tests. If the labels are not wide enough, the test may print on the platen 
roller and damage it.
Note • 
When performing a self test, do not send a label format to the printer. For remote hosts, 
disconnect all data interface cables from the printer. For printers in Peel-Off Mode, remove the 
labels as they come out of the printer.