Senstar LM100 calibration
Page 54
Senstar LM100 Product Guide
Senstar LM100 calibration
When calibrating the Senstar LM100 for the first time, begin with the detection parameters in the 
default settings.
The Sensitivity Profile
A Sensitivity Profile should be recorded for the full length of the protected fence. The Sensitivity 
Profile records each luminaire’s measured response to a consistent fence disturbance. The profile 
will verify the luminaire’s detection performance and can identify problems on the fence, or 
problems with a luminaire’s attachment.
Recording the Sensitivity Profile
The recommended method for creating the Sensitivity Profile is to drag a screwdriver or similar 
instrument along the fence fabric at a consistent height below, the luminaires. Beginning at the 
luminaire AP (or the designated first luminaire according to the Head Sequence table) place the 
screwdriver against the fence fabric and apply consistent pressure as you walk along the side of 
the fence. Keep the pressure steady and maintain a uniform pace as you drag the screwdriver 
along the fence fabric. When you reach the first fence post, lift the screwdriver over the post. 
Continue dragging the screwdriver along the fence fabric maintaining a consistent distance below 
the luminaires and lifting the screwdriver over each fence post until you reach the end of the 
protected fence. Keep the pressure of the screwdriver and your walking pace as consistent as 
possible. Repeat this process from the end of the protected fence back to the start point.   
Figure 50: Sensitivity Profile
raw sensitivity profile data
(gray line)
use the controls in the Profile field
select the Record button to start
recording the profile
(becomes Stop button while recording)
to setup the profile being recorded