System test procedure
Page 66
Senstar LM100 Product Guide
•
Cut detection - Use the tap test, or weave a piece of scrap fence wire into the fabric of the
fence and cut the scrap wire. Test each zone in at least three separate locations.
At each location, tap the fence fabric, or cut the scrap wire, the number of times specified by
the Event Count parameter + 1. Wait at least 2 seconds between taps.
fence and cut the scrap wire. Test each zone in at least three separate locations.
At each location, tap the fence fabric, or cut the scrap wire, the number of times specified by
the Event Count parameter + 1. Wait at least 2 seconds between taps.
PASS ____ FAIL____
•
Climb detection - Have a tester climb on the fence fabric for at least as long as it would take
to climb over the fence (or use the screwdriver drag method). Repeat the climb simulation in at
least three locations per zone.
to climb over the fence (or use the screwdriver drag method). Repeat the climb simulation in at
least three locations per zone.
PASS ____ FAIL____
•
Fence lift detection (This test may not be possible on a number of fence types. Use care to
ensure that the fence is not damaged during this test) - Have a tester lift or pry up the bottom
the fence fabric for a minimum of the Event Time X the Event Count (depending on the amount
of fence noise being generated, the test may have to exceed the Event Time setting by several
seconds). Repeat the lift test in at least three locations per zone.
ensure that the fence is not damaged during this test) - Have a tester lift or pry up the bottom
the fence fabric for a minimum of the Event Time X the Event Count (depending on the amount
of fence noise being generated, the test may have to exceed the Event Time setting by several
seconds). Repeat the lift test in at least three locations per zone.
PASS ____ FAIL____
•
Enclosure tamper - Open the gateway’s enclosure. The DOOR OPEN LED (D1) turns ON,
and the UCM Enclosure Tamper indicator turns ON, and the Event log reports an Enclosure
Tamper alarm. If a relay is configured to activate for an enclosure tamper, the designated relay
activates.
and the UCM Enclosure Tamper indicator turns ON, and the Event log reports an Enclosure
Tamper alarm. If a relay is configured to activate for an enclosure tamper, the designated relay
activates.
PASS ____ FAIL____
•
Auxiliary inputs - For Local control mode the Aux inputs activate luminaire zones. In this
case, activate the input, and verify that the specified luminaire zone activates in response.
For Remote control mode, the Aux inputs serve as auxiliary device inputs to the host Security
Management System. In this case, activate the connected device, and verify the status
change is reported by the host SMS. Repeat for each configured input.
case, activate the input, and verify that the specified luminaire zone activates in response.
For Remote control mode, the Aux inputs serve as auxiliary device inputs to the host Security
Management System. In this case, activate the connected device, and verify the status
change is reported by the host SMS. Repeat for each configured input.
PASS ____ FAIL____
•
Relay outputs - For Local control mode the relay outputs are used to report events. Cause an
event, and verify that the configured relay activates for a minimum of the relay hold time. Verify
that the connected device activates. Repeat this procedure for each specified event.
For Remote control mode, the relays serve as output control points for the host SMS. Send an
activation command from the host SMS to a relay and verify that the relay activates. Verify that
the connected device activates. Repeat this procedure for each relay.
event, and verify that the configured relay activates for a minimum of the relay hold time. Verify
that the connected device activates. Repeat this procedure for each specified event.
For Remote control mode, the relays serve as output control points for the host SMS. Send an
activation command from the host SMS to a relay and verify that the relay activates. Verify that
the connected device activates. Repeat this procedure for each relay.
PASS ____ FAIL____
•
Normal Light Control - If a schedule has been setup to activate luminaire zones at specific
times on specified days, verify that the luminaire zones activate and deactivate according to
the schedule.
times on specified days, verify that the luminaire zones activate and deactivate according to
the schedule.
PASS ____ FAIL____
•
Auto Light Control - For luminaire zones that are setup to activate in response to alarm
conditions, simulate an alarm and verify that the luminaire zone activates as specified.
conditions, simulate an alarm and verify that the luminaire zone activates as specified.
PASS ____ FAIL____