Garmin International Inc 01337 用户手册
GHP 10 Marine Autopilot System Installation Instructions
Appendix
Specifications
ECU
ECU
Physical
Dimensions (W×H×D):
6
19
/
32
in. × 4
19
/
32
in. × 2 in. (167.6 mm × 116.8 mm × 50.8 mm)
Weight:
1.5 lb. (0.68 kg)
temperature Range:
from 5°F to 131°F (from -15°C to 55°C)
Case Material:
Fully gasketed, high-impact aluminum alloy, waterproof to IEC 529 IPX7 standards
Power Cable Length:
9 ft. (2.7 m)
Power
input Power:
11.5–14 Vdc
Fuse:
40 A
Main Power usage:
1 A (not including the pump)
CCU
Physical
Dimensions:
3
19
/
32
in. diameter (91.4 mm)
Weight:
5.6 oz. (159 g)
temperature Range:
from 5°F to 131°F (from -15°C to 55°C)
Case Material:
Fully gasketed, high-impact plastic alloy, waterproof to IEC 529 IPX7 standards
CCU/ECU Interconnect Cable Length: 9
1
/
2
ft. (3 m)
Power
NMea 2000 Power input:
9–16 Vdc
NMea 2000 LeN:
2 (100 mA)
1.2L/2.0L Pump
Physical
Dimensions (W×H×D):
11 in. × 4
11
/
16
in. × 3
11
/
16
in. (279.4 mm × 119.4 mm × 94 mm)
Weight:
8.05 lb. (3.65 kg)
temperature Range:
from 5°F to 131°F (from -15°C to 55°C)
Cable Length:
19 in. (0.5 m)
Power
Main Power usage:
Varies based on hydraulic loading
2.1L Pump
Physical
Dimensions (W×H×D):
15 in. × 7
1
/
2
in. × 7
3
/
16
in. (381 mm ×190.5 mm × 182.9 mm)
Weight:
17.6 lb. (8 kg)
temperature Range:
from 5°F to 131°F (from -15°C to 55°C)
Cable Length:
19 in. (0.5 m)
Power
Main Power usage:
Varies based on hydraulic loading