Davis Instruments DWW765Y 用户手册

下载
页码 35
15
Verifying Repeater Communication with a Console
The console is configured the same way it is configured in a Single Repeater installation, 
except that the repeater ID that is selected is the last repeater in the chain.
On the Console in Screen 2: Configuring Transmitter IDs:
1. Find the transmitter ID transmitting through the repeater, and if the station is not 
already toggled on with it’s station type selected, do so now. Turn the station on by 
pressing the up arrow until “ON” displays on the screen. Change the station type by 
pressing GRAPH until the correct station type displays.
2. Press WIND to turn the repeater function on and to display repeater ID information. 
Keep pressing WIND until the Repeater ID for the last repeater in the chain is dis-
played.
3. Press DONE to continue to the other screens in the Setup Mode, or press and hold 
DONE to return to the Current Weather Mode.
Note: See 
the 
Vantage Pro2 console manual for more information on the screens in the Setup Mode if 
necessary.
To verify that setup was successful, in the console’s current mode:
1. View the transmitter information displaying at the bottom of the console screen. 
If the transmitter ID being repeated is displayed and an “X” displays in the bottom 
right-hand corner of the ticker tape, the transmitter is being repeated and received by 
the console successfully.
Multiple Transmitters, One Repeater 
Installation
A multiple transmitter, one repeater installation differs from a single repeater installation 
only in the number of transmitters the repeater listens to and retransmits. See “Single 
Repeater Installation” on page 8 for detailed instructions on configuring the transmitter 
and console for wireless repeater use.
This section covers the additional steps necessary to get a chain of repeaters set up and 
communicating.
Verifying Repeater ID
The wireless repeater contains a DIP switch used to program the repeater with a unique 
identification. DIP switches #1, 2 and 3 on the repeater are used in the same way that DIP 
switches are used on all stations.The default repeater ID is A and the default position for 
the DIP switches is down or OFF
Note: 
For Single Repeater Installations, the repeater should remain on the default ID of A and should not 
be changed.
                      1