SYSTEM OPERATION 
 
 
8.  Output Update Rate:  The DRU III can be set to 
output packets of speed data at rates of (8 times per 
second, 4 times a second, 2 times a second, once a 
second, upon speed change, or when the user’s 
equipment polls for data) 
 
Note: If Output Update Rate is set to upon speed 
change, the DRU III outputs speeds immediately 
when the speeds changes by at least one unit or once 
every two seconds if the speed is not changing.   
If the DRU III is set to the Polled output, data is 
output when the DRU III receives characters [“*P”] 
or [“*P”0x0D]. 
 
9.  During the configuration session, the Status box will 
display information about the connected DRU III and 
the status of the configuration operations. 
  
To configure your DRU III unit, connect the DRU III data 
connector to the PC comm. port 1 and apply power to the 
DRU III.  Click the Reset & Capture button to capture the 
DRU III for configuration.  You can click the Read Settings 
button to populate the configuration screen with the current 
DRU III settings.  Make any required changes in the 
configuration options and click the Write Settings to store 
these changes in the DRU III.  When finished, click the 
Release button to return the DRU III to normal operation 
with the new configuration settings.