Table 4 indicates maximum wiring distances per Wiegand standard with 
the three most common gauges of cable.
INSTALLATION NOTES
Unless otherwise specified in this document, please follow the guidelines 
below:
1. Shielded cable is recommended in electrically noisy environments.
2. You may use a local power supply for the reader. If so, do not connect 
the power supply from the controller to the reader. The ground line of 
the local power supply must be connected to the power supply of the 
controller
.                                         The unit needs to be operated with a power source with limited
                                                                                     power consumption according to EN 60950-1 (2003) paragraph 2.5.
                                                                                     3. Use of a pull-up resistor may be required by some controllers. Consult 
                                                                                     your controller manual.
                                                                                                                           4. For tamper wiring, connect Pins 11 and 12 to a normally closed 
                                                                                                                          supervised input, as shown in Figure 3
.
  
 
 
   
  
                                                                                                               
                          FIGURE 3.  Normally Closed Wiring for Reader Tamper
TABLE 4. Maximum cable distance for 18, 20, or 22 AWG wire
Wire Gauge
18 AWG
20AWG
22 AWG
Cable 
Distance
500 feet 
(152 meters)
300 feet
(91 meters)
200 feet
(61 meters)