WIRING
The Model SWH-1100 has twelve terminals as noted in Table 3. The 
terminal strip is removable for easy installation and wiring. When attaching 
wires to the connector, strip off only the minimum insulation required 
(approx. 1/8'') and push the wire into the connector until the insulation is 
flush or inside the connector body. This is particularly critical for outdoor 
readers. While the reader itself is designed and protected to IP65 standards, 
the cable wires can potentially corrode and short together if not carefully 
mounted and tightly fastened in the connector body.
Table 4 indicates maximum wiring distances per Wiegand standard with 
the three most common gauges of cable.
TABLE 3.  Connector Pins for Model SWH-1100
Pin
Description
Pin
1
External Beeper Control
7
External Green LED Control
2
Ground
8
External Red LED Control
3
Power (8 to 16 VDC)
9
Reserved for future use
4
D1 Wiegand
10
Reserved for future use
5
D0 Wiegand
11
Tamper (Normally Closed)
6
Reserved for Future Use
12
Tamper (Normally Closed)
TABLE 4. Maximum cable distance for 18, 20, or 22 AWG wire
Wire Gauge
18 AWG
20AWG
22 AWG
Cable 
Distance
500 feet 
(152 meters)
300 feet
(91 meters)
200 feet
(61 meters)