2. Technical Data
Dimensions (mm):
172 x 148 x 40
Weight:
approx. 730 g (without steel sides)
approx. 1500 g (with steel sides)
Material:
PA6, black (front of housing)
PMMA (back of housing)
steel (sides; PS1 optional)
Protection Class:
IP 65
Operating Temperature:
-25 °C...+50 °C
Storage Temperature:
-40 °C...+85 °C
Voltage Supply:
12...24 V/DC via M8 (4-pole)
Power Consumption:
7 W (operating status) / 2.5 W (standby)
Transmission Frequency:
865-868 MHz (EU)
902-928 MHz (US)
Antenna:
Beam Width:
90°
Polarization:
circular (LHCP)
Reading/Writing Distance: up to 1.5 m, depending on type of transponder 
and environmental conditions
Radiated Transmit Power:
max. 200 mW E.R.P.  (ETSI EN 302 208),
330 mW E.I.R.P.  (FCC Part.15), optional
Transponder Protocols:
ISO 18000-6 C
EPC Class 1 Gen 2
Interfaces:
RS485
Bluetooth™ Class 1 (optional)
Anticollision:
simultaneous reading of several transponders
Reading Mode:
Dense Reader Mode can be activated
Ultrasonic Sensor:
range up to 70 cm distance
Signalling (optical):
LEDs (yellow, green, red)
Conformity:
(Exposition of persons
EN 50364
against EM fields)
EMV
EN 301 489
Air interface (EU)
EN 302 208 (DRM)
V08/07/09