Roseman Engineering Ltd. FG3E 用户手册
Fleet Gate Installation Guide Roseman Engineering Ltd
20
The Fueling Division of Roseman Engineering Ltd.
6. Wiring the Dallas TAG reader set
6.1
Mounting the Vehicle Dallas TAG Reader Set
1. Mount the Dallas TAG Reader Combined under the vehicle dashboard.
2. Route the Grey Cable #ACC-CB-15A from FJ3 to TAG Reader Combined.
3. Mount the Cable Reader Dallas TAG #ACC-CB-B7 on the dashboard near the driver.
6.2 Connecting the FJ3 to Dallas TAG reader set
1. Connect the 4 wire grey cable #ACC-CB-15A to FJ3 terminals as follows:
Connect the White wire to DALLAS LED terminal
Connect the Green wire to DALLAS IN terminal
Connect the Black wire to (-) BAT OUT terminal
Connect the Red wire to (+) BAT OUT terminal
Connect the Green wire to DALLAS IN terminal
Connect the Black wire to (-) BAT OUT terminal
Connect the Red wire to (+) BAT OUT terminal
2. Connect the 4 pin connector of cable #ACC-CB-B7 to TAG Reader Combined as
shown.
Figure 8: Wiring Dallas TAG Reader Set
Cable Button
Reader Dallas
#ACC-CB-15A
Cable Reader Dallas TAG
#ACC-CB-B7
TAG Reader Combined
#RDR-02-01
FJ3