Multi-GAP Mode  
To  put  the  unit  in  Multi-GAP  (Gate  Access 
Panel)  Mode,  place  dipswitch  #1  DOWN 
(towards the circuit board) placing the unit 
into “Passive” mode.  This unit will now act 
as  an  accessory  to  an  “Active”  GAP  or 
“Active” MiniGAP2 module within an Oracle 
System Network, customarily used at a side 
or back entrance. Any accessories that had 
been  previously  activated  to  a  “Passive” 
MiniGAP2  will  have  to  be  re-activated  to 
the “Active” GAP or MiniGAP2 unit.  
 
In  Multi-GAP  mode,  when  activating 
multiple  GCU’s,  each  additional  GCU  must 
be activated as the #1 unit to the “Active” 
GAP or MiniGAP2.  After any additional GCU 
has been activated, it will then need to be 
set  as  the  #2
 
or  #3  GCU  by  using  chart  #2 
below,  to  correspond  with  the  “Passive” 
MiniGAP2, set using chart #1 below. 
Note:   If you  have 2 or  3 GCU’s and you fail to 
give each one their own Identity (1,2, or 3) and 
leave each GCU set as unit #1, the units will fail 
to function. 
 
Changing GCU dipswitches #1&2 in the Gate 
Control Unit sets the GCU’s Identity. 
  
 
GCU  
IDENTITY 
MiniGAP2
SW1 
MiniGAP2
SW2 
off 
off 
on 
off 
off 
on 
 
 
GCU 
IDENTITY 
GCU 
SW1 
GCU 
SW2 
off 
off 
on 
off 
off 
on 
 
Clearing the Mini-GAP2’s Memory 
Note:    Clear  the  memory  only  for  a new Multi-GAP  mode 
set-up. 
Clear the MiniGAP2’s memory by switching 
dipswitch #1 DOWN and holding down the 
LEARN button for ten seconds. It will sound a 
tone indicating the memory has been 
cleared. 
Note:  A MiniGAP2 in “Active” mode does NOT need to 
have its memory cleared. 
 
Basic  Gate  Control  Unit  (GCU) 
Installation 
Mount  the  Oracle  Gate  Controller  near  your 
Automatic  Gate  Opener’s  control  motor.    Most 
gate  motors  have  simple  relay  connections  (often 
labeled  COMMON  and  CYCLE)  that  connect  to 
the  two  large  OPEN/CLOSE  relay  outputs  of  the 
GCU. 
 
(See Gate Control Module installation manual 
for complete Gate Controller Configuration.) 
 
Adjusting the MiniGAP2 Speaker 
volume and Microphone Sensitivity 
To  increase  the  Outdoor  Intercom’s  volume,  switch 
dipswitch #4 UP (away from the circuit board). 
 
To  increase  the  Outdoor  Intercom’s  microphone 
sensitivity,  switch  dipswitch  #3  UP  (away  from  the 
circuit board).   
 
Troubleshooting and Frequently Asked Questions 
 
Nothing Happens. The MiniGAP2 Does Not Function 
Make sure that the Intercom has fresh batteries in it. When you press the CALL button, you should hear a tone. If 
the units have power but do not communicate, they may need to form a network. Press the LEARN button on each unit 
that needs to form a network and they will beep in response.   
You may need to clear their memory and re-teach them.  
Dipswitch  #1  is  normally  UP  (away  from  the  circuit  board).    In  the  DOWN  position  it  will  not  operate  unless  it  is 
taught to an Oracle Network, as a passive unit (See MULTI-GAP MODE).
  
 
The MiniGAP2 is Not Getting the Expected Transmission Range 
Trees, metal, electrical wiring or other electrical devices directly between units can limit the range, as can having it 
mounted on a tree, masonry, or metal surface.  
 
I hear a warbling two-tone error sound when I activate the Gate Controller? 
The MiniGAP2 unit is not communicating with the GCU. The GCU may be out of range. If the units work properly when 
close  together,  the  GCU  may  need  to  be mounted  higher  off  the  ground  or  on  a  different  surface.  Metal,  trees,  or 
masonry cause the most interference.  
 
If the units do not work when close together, the MiniGAP2 has not mated with that GCU. Double-check the GCU’s ID 
(as set with dipswitches 1 & 2, and re-teach it.
  
MiniGAP2 
Dipswitch 
Settings 
GCU 
Dipswitch 
Settings 
#1 
#2