Chamberlain Wireless Products Inc. OPB2 用户手册
RELAY HOLD MODE
ULTRA RX 900-3
3 BUTTON ACCESS
POWER SAVE MODE
- 2 -
- 3 -
TEACHING A 3 BUTTON ACCESS TO AN ULTRA RX 900-3
ERASING THE MEMORY OF THE ULTRX 900-3
+ -
POWER
Pin 1 and 2 for 10 – 24 VAC
Pin 1 and 3 for 10 – 24 VDC
CONNECT THE ULTRA RX 900-3
OUTPUT TIMING
To place the Ultra RX 900-3 in Learn Mode:
Disconnect the power and wait at least 5 seconds.
Reapply the power. (The LED will illuminate until the Learn period has expired.
When the Learn period has expired, the Ultra RX 900-3 will buzz.)
Within 10 seconds, press the learn button on the 3 Button Access unit.
You will hear the RX 900-3 buzz and the 3 Button Access will sound a tone
indicating the units have learned successfully.
If you have additional 3 Button Access units, they can each be taught within 10
seconds of each other or later by repeating this process. If a 3 Button Access
unit was newly taught, the LED on the RX 900-3 will blink 3 times slowly. If NO
new units were taught the LED will display 4 blinks, 4 times.
Once you are done teaching 3 Button Access units, wait 10 seconds for the
Ultra RX 900-3 to leave learn mode. The unit will buzz indicating the Learn
period is over and the units are ready to use.
Disconnect the power and wait at least 5 seconds.
Reapply the power. (The LED will illuminate until the Learn period has expired.
When the Learn period has expired, the Ultra RX 900-3 will buzz.)
Within 10 seconds, press the learn button on the 3 Button Access unit.
You will hear the RX 900-3 buzz and the 3 Button Access will sound a tone
indicating the units have learned successfully.
If you have additional 3 Button Access units, they can each be taught within 10
seconds of each other or later by repeating this process. If a 3 Button Access
unit was newly taught, the LED on the RX 900-3 will blink 3 times slowly. If NO
new units were taught the LED will display 4 blinks, 4 times.
Once you are done teaching 3 Button Access units, wait 10 seconds for the
Ultra RX 900-3 to leave learn mode. The unit will buzz indicating the Learn
period is over and the units are ready to use.
RELAY 1
Timing modes are determined utilizing the dipswitch located inside the unit. This can be
accessed by removing the 1 screw on the bottom of the unit.
RELAY 2
RELAY 3
The 3 Button Access is ONLY compatible with the Ultra RX 900-3. Up to 8 3 Button
Access units can be taught to 1 Ultra RX 900-3.
NOTE: ONLY 1 Ultra RX 900-3 can be taught to 3 Button Access units. A 3 Button
Access CANNOT be used to control multiple Ultra RX 900-3 units.
Access units can be taught to 1 Ultra RX 900-3.
NOTE: ONLY 1 Ultra RX 900-3 can be taught to 3 Button Access units. A 3 Button
Access CANNOT be used to control multiple Ultra RX 900-3 units.
Install 4 ‘AA’ batteries into the 3 Button Access. Lithium are preferred in cold climates.
-
Button 1 (GREEN) operates Relay 1
-
Button 2 (WHITE) operates Relay 2
-
Button 3 (RED) operates Relay 3 and releases Relays 1 and 2
To reduce the power consumption of the Ultra RX 900-3, dipswitch 7 should be
on. This will not take effect until a button is pressed on EACH of the learned 3
Button Access units.
on. This will not take effect until a button is pressed on EACH of the learned 3
Button Access units.
With dipswitch 8 turned ON, the Ultra RX 900-3 will hold a relay, corresponding
to the correct button pressed on the 3 Button Access unit, until the button is
released.
to the correct button pressed on the 3 Button Access unit, until the button is
released.
-
Remove the screw on the back of the unit.
-
Press and hold the LEARN button until the LED double blinks, 3 times.
o The RX 900 Unit has 3 Relays:
• Relay 1:
Pin 11 – Common
Pin 12 – Ch 1 Normal Open
Pin 13 - Ch 1 Normal Closed
• Relay 2:
Pin 8 – Common
Pin 9 – Ch 2 Normal Open
Pin 10 - Ch 2 Normal Closed
• Relay 3:
Pin 6 – Common
Pin 7 – Ch 3 Normal Open
Pin 5 - Ch 3 Normal Closed
RELAY OUTPUTS
OPB3
Patents Pending
4/3/2007