Easy Fuel Plus  Rf Nozzle  
Version 2.01 
EFP RF Nozzle 
 
Confidential & Proprietary 
page 3 
SC
Site Controller
Host
230/110
VAC
UHF communication 
(433/902-928MHz)
Site Office
RS232/485
RF Nozzle
Vehicle
RF
Unit
Nozzle
RFID Antenna
13,56
MHz
Vehicle Fuel Inlet
NID Antenna
Passive RFID Vehicle Tag or 
FIC (Fuel inlet Coil)
FIC
TAG
 
Figure 
 2-1: RF Nozzle System Block Diagram 
2.3 Operational 
Scenarios 
Vehicle with passive RFID tag:  
When the nozzle is inserted into the vehicle refueling inlet the RFN reads data from the 
passive RFID vehicle tag and transmits it together with its own identity to the site 
controller. Fuel is dispensed once the transaction is authorized. Fuel is dispensed as 
long as the RF Nozzle detects the presence of the passive RFID tag. If the nozzle is 
retracted from the refueling inlet so that the RFID tag is not detected the RFN informs 
the system to stop dispensing fuel.