6.
  Module Control 
6.1
   Power off and reset limitations 
There is no limitations to power off and reset. 
 
 
6.2
   Power supply interrupt 
If MAINVCC drops out of range(<3.05V 1usec typ) then the module is completely shut down. 
In thie case, please execute power-on sequence. 
 
 
6.3
   Over-temperature Protection 
PM8018 provides over-temperature protection. If PM8018 die temperature greater than 150 °C, 
the module is completely shut down.
 
Temperature hysteresis is incorporated such that the die 
temperature must cool significantly (<110°C typ) before the module can be powered on again. 
When  the  module  bocome  under  110°C(typ)  and  a  PWR_N  signal  is  enabled,  the  module  will 
power up. 
Please execute power-on sequence. 
 
 
6.4
   Over-temperature Protection (restricted RF operation). 
The thermistor built into the module (around Power Amplifier) detects the temperature around it. 
Based on the detected limited temperature, the module starts or terminates temperature protec-
tion and stop transmit/receive functions to prevent devices to be destructed.