Load Specifications
Control
Load Type
Min. 
Load
Max. 
Load
SZ-1SD
Incandescent
10 W
150 W
Halogen
10 W
100 W
Compact 
fluorescent
10 W
30 W
 
Important Notes
Install in accordance with all local and 
national electrical codes.
Environment: Ambient operating 
temperature: 32 to 104 °F (0 to 40 °C),  
0 to 90% humidity, non-condensing. 
Indoor use only.
Cleaning: To clean, wipe with a clean 
damp cloth. 
Do NoT use any chemical 
cleaning solutions.
RF Device Placement: RF dimmers 
and switches must be located within 20 
feet (6 m) of an RF signal repeater or a 
device configured as a repeater.
Stanza RF dimmers or switches cannot 
be controlled by the system until they 
are addressed and programmed. They 
will work as stand-alone controls only.
Range and performance of the Stanza 
system are dependent on a variety of 
factors, including:
•  Distance between system components
•  Geometry of the space
•  Construction of walls separating 
system
•  Electrical equipment located near the 
system components
•  Position of the lamp socket dimmer/
switch.
Lamp requirements: Do not use 
dimmer to control table lamps with 
touch control or with integral dimmers. 
Lamps without integral switches are 
recommended; lamps with integral 
switches must be set to full on, then the 
switch should be disabled or removed.
The lamp socket dimmer/switch may 
be installed in any orientation between 
vertical and 90° from vertical. When 
installed in any orientation other than 
vertical, derating is required.
Derating Chart 
orientation
Load Type
Rating
Vertical
Incandescent
150 W
Halogen
100 W
10 to 90
°
  
from vertical
Incandescent
100 W
Halogen
75 W
 
1.  Find a suitable location for the lamp 
socket dimmer/switch. The dimmer/
switch must be within 20 feet (6 m) of 
a device configured as a repeater. If 
there is a switch on the lamp, make 
sure it is in the full on position, and 
remove or disable it if possible.
2.  Unplug the lamp 
cord from the wall 
receptacle.
3.  Remove 
the lamp 
harp.
4.  Remove 
the lamp 
bulb, and 
screw 
the lamp 
socket 
dimmer/
switch into 
the lamp 
socket. 
Replace the 
bulb into 
the lamp socket dimmer/switch.
5.  Reinstall the lamp harp (rotate it to 
clear the lamp socket dimmer/switch 
if necessary). If desired, install the 
optional harp lock using the provided 
hex wrench.
6.  Plug the lamp cord 
into the wall socket.
 
    Dimming Knob
•  Turn clockwise to turn on and 
brighten
•  Turn counter-clockwise to dim and 
turn off
•  Push in to toggle on and off
•  Push in and hold to enter program-
ming mode
•  Audible sound indicates when high 
and low levels are reached
  Status Indicator
•  Indicates current load status
•  Green = load is switched on
•  Off = load is switched off
•  Amber = device is in programming 
mode
•  Red = device is experiencing an over-
temperature condition
  operation Notes
•  
The lamp socket dimmer/switch 
should immediately control the bulb 
once power is applied.
•  When initially installed, the lamp 
socket dimmer/switch functions only 
as a switch, which allows it to control 
non-dimmable compact fluorescent 
bulbs. To also dim incandescent 
loads, it must first be addressed as 
part of a Stanza system.
•  The lamp socket dimmer/switch 
cannot be controlled over radio 
frequency (RF) from a keypad or 
contact closure input until it has been 
addressed as part of a Stanza system.
   Returning the Dimmer/Switch to  
Factory Settings
1.  Triple-tap the dimming knob quickly 
(within 1 second).
2.  Press and hold the dimming knob for 
5 seconds (until the load flashes).
3.  Triple-tap the dimming knob quickly 
again.
  Notes
•  Returning to factory settings will 
clear all programming from the lamp 
socket dimmer/switch device, and will 
prevent it from being controlled over 
RF from a keypad or control interface.
•  After being returned to factory 
defaults, the device will need to be re-
addressed as part of a system.
•  The device will revert to switching 
operation, so non-dimmed compact 
fluorescent loads can be controlled. 
Incandescent loads then cannot be 
controlled until the device has been 
re-addressed as part of a system. 
Otherwise, damage to the device or 
bulb may occur.
Installation Instructions
Please Read Before Installing
Lamp Socket Dimmer/Switch
Stanza
TM
Stanza
TM
 Lamp Socket  
Dimmer/Switch
SZ-1SD-TP
120 V   50 / 60 Hz
Installation
operation
Remove 
lamp harp.
Install lamp 
socket.
Tighten harp 
lock.
Caution! To avoid risk of elec-
trical shock, do not attempt 
to open the lamp socket 
dimmer / switch. Unplug the table lamp 
before changing the light bulb.
Lutron Electronics Co., Inc.
Made and printed in the U.S.A.
P/N 030-996 Rev. A 6 /08
Technical support:  USA, Canada, Caribbean: 1.800.523.9466 
Mexico: +1.888.235.2910 
Central/South America: +1.610.282.6701
Warranty: 1-year limited warranty standard. 2-year parts and labor warranty, with 
8-year pro-rated parts replacement on commissioned systems.
These products may be covered under one or more of the following U.S. patents: 5,248,919; 
5,838,226; 5,848,054; 5,905,442; 6,687,487; 6,803,728; and corresponding foreign patents. 
U.S. and foreign patents pending. Lutron and the sunburst logo are registered trademarks and 
Stanza is a trademark of Lutron Electronics Co., Inc.
© 2008 Lutron Electronics Co., Inc.
R
Dimming 
knob
Status 
indicator
Troubleshooting Guide
Symptom
Cause and Action
Light does 
not turn 
on, but 
the status 
indicator is 
on.
Light bulb/lamp is 
burned out or not 
installed.
•   Replace or install 
lamps.
Light does 
not turn on, 
and the sta-
tus indicator 
is off.
Power is off
•   Check the circuit 
breaker and make 
sure it is on.
Lamp is unplugged
•  Check that the 
lamp cord is 
plugged into the 
wall socket.
Lamp has an integral 
switch
•  Make sure the 
lamp’s integral 
switch is set to 
full on.
Dimmer 
does not 
dim properly 
and/or flick-
ers.
Lamp has an integral 
dimmer
•  Use a lamp without 
a dimmer.
Bulb is not 
dimmable
•  Replace bulb with 
incandescent bulb.
FCC Information
Note: This equipment has been tested and found to comply with 
the limits for a Class B digital device pursuant to Part 15 of the 
FCC rules. Operation is subject to the following: (1) This device 
may not cause harmul interference, and (2) this device must 
accept any interference received, incouding interference that 
may cause undesired operation.