Lutron Electronics Company Inc 0066 用户手册

下载
页码 1
RF Lamp Dimmer 
RRD-3LD
120 V   50 / 60 Hz
Installation Instructions
Please Read Before Installing
Troubleshooting Guide
Symptom
Probable Cause and Action
Light does not turn ON, but 
LEDs on Lamp Dimmer are 
ON
Switch on lamp is turned OFF
   
  Turn lamp switch to full ON.
Lightbulbs are burned out or not installed
   
   Replace or install lightbulbs.
Dioded lightbulbs
   
   If dioded lightbulbs are being used, 
replace with non-dioded lightbulbs.
Light does not turn ON, and 
LEDs on Lamp Dimmer are 
OFF
Circuit breaker is OFF
   
  Turn circuit breaker ON.
Cord is not plugged in
   
 Plug cord into wall outlet as shown  
in Installation.
Lamp Dimmer does not dim 
properly or lights flicker
Lamp has an integral dimmer
   
  Use lamp without an integral dimmer.
3-way switch on lamp is not set to full ON
   
  Turn 3-way switch on lamp to full ON
Lights don’t turn ON / OFF 
from Keypad or Integrated 
Scene Controller
Improper programming
   
 Program according to the  
     RadioRA-SR Setup Guide.
Out of RF range
   
 Reposition to be within 30 ft (9 m)  
     of controlling keypads or an Integrated 
     Scene Controller.
Lamp Dimmer is warm
Solid-state control dissipation
   
  Solid-state dimmers internally dissipate 
about 2% of the total connected load. 
It is normal for dimmers to feel warm to 
the touch during operation.
Load Specifications:
Lamp 
Dimmer
Load 
Type
Min. 
Load
Max. 
Load
RRD-3LD
Incand.
10 W
300 W
MLV
10 W / VA
200 W /  
300 VA
Use these instructions to install the  
model numbers listed above. For  
system setup instructions and tools visit:  
www.lutron.com/radiora2
Warranty: 
For warranty information, please see the warranty enclosed with 
the product, or visit www.lutron.com/resiinfo.
These products may be covered under one or more of the following U.S.  
patents: 5,248,919; 5,399,940; 5,637,930; 5,838,226; 5,848,054; 5,905,442; 
6,687,487; 6,803,728; D439,220 and corresponding foreign patents. U.S. and 
foreign patents pending. Lutron, RadioRA and the sunburst logo are registered 
trademarks of Lutron Electronics Co., Inc.   
©2009 Lutron Electronics Co., Inc.
Technical Assistance: 
U.S.A. / Canada: 1.800.523.9466 
Mexico: +1.888.235.2910 
Other Countries: +1.610.282.3800  
24 hours a day, 7 days a week.
Lutron Elec tron ics Co., Inc. 
7200 Suter Road
Coopersburg, PA 18036-1299
Made and print ed in the U.S.A.  8 / 09 P/N 044-163 Rev. A
Returning Lamp Dimmers to Factory Settings 
 
Note: Returning a Lamp Dimmer to its Factory Settings will remove the Lamp 
Dimmer from the system and erase all programming.
1.  Triple-tap and hold the tapswitch. DO NOT release after third tap.
2.  Continue to hold the tapswitch on the third tap until LEDs start to scroll up and 
down quickly (approximately 3 seconds).
3.  Release the tapswitch and immediately triple-tap it again. The LEDs will scroll 
up and down slowly. When the LEDs stop scrolling, the Lamp Dimmer has been 
returned to Factory Settings.
Installation 
1.   Find a suitable location for the RF Lamp Dimmer. Place the RF Lamp  
Dimmer in a convenient and accessible location. 
 
      
2.   Turn lamp OFF and unplug lamp cord from wall outlet.
3.   Plug lamp cord into the RF Lamp Dimmer plug.
4.   Plug RF Lamp Dimmer into any standard wall outlet.
5.   Turn lamp switch ON and operate RF Lamp Dimmer.
 WARNING: To avoid risk of electrical shock, unplug Lamp Dimmer  
when changing light bulbs. Changing light bulbs with the power on  
could result in personal injury or death.
 
WARNING: To avoid risk of electrical shock, do not open, cut cord,  
or rewire device. Modification of the device can result in personal  
injury or death.
Note: This is a POLARIZED cord set. It has a polarized plug (one blade  
is wider than the other) and outlet (one slot is wider than the other). 
The polarized plug is not intended to be mated with nonpolarized outlets  
(having both slots the same size). 
A polarized outlet is intended to mate with a polarized plug in only one way  
(the longer slot with the wider blade).
Status LEDs
Indicate light level; glow softly as 
night light when lamp is off
Tapswitch
Tap on/off; double-tap for full on; 
press and hold (while ON) for 
10-second long fade-to-off
Dimming Rocker
Press to Brighten
Press to Dim
English
WARNING: To avoid the risk of entrapment, serious injury, or death, these 
controls must not be used to control equipment which is not visible from 
every control location or which could create hazardous situations such 
as entrapment if operated accidentally. Examples of such equipment 
which must not be operated by these controls include (but are not limited 
to) motorized gates, garage doors, industrial doors, microwave ovens, 
heating pads, etc. It is the installer’s responsibility to ensure that the 
equipment being controlled is visible from every control location and that 
only suitable equipment is connected to these controls. Failure to do so 
could result in serious injury or death.  
 
NOTICE: To avoid overheating and possible damage to other equipment, 
do not use to control motor-operated or transformer-supplied appliances or 
other non-lighting loads. 
 
Codes: Install in accordance with all local and national electrical codes. 
 
Environment: Ambient operating temperature: 32 °F to 104 °F  
(0 °C to 40 °C), 0% to 90% humidity, non-condensing. Indoor use only. 
 
Cordset: The cordset length is 6 ft (1.8 m). 
 
Cleaning: To clean, wipe with a clean damp cloth. DO NOT use any 
chemical cleaning solutions. 
Lamp Type: Lamp Dimmers are designed for use with incandescent, 
magnetic low-voltage, and tungsten halogen lightbulbs only. Do not use 
to control fluorescent lightbulbs or table lamps with an integral dimmer or 
touch lamps. For lamps with integral 3-way switches, switch should be set 
to full on position. Lamp Dimmers may not work with dioded lightbulbs. 
 
Low-voltage Applications: Use Lamp Dimmers with magnetic (core 
and coil) low-voltage lamps only. Not for use with electronic (solid-state) 
low-voltage lamps. Operation of a low-voltage circuit with lightbulbs 
inoperative or removed may result in transformer overheating and 
premature failure. Lutron strongly recommends the following: 
 
  Do not operate low-voltage circuits without operative lightbulbs in 
place.
 
  Replace burned-out lightbulbs as quickly as possible.
 
  Use transformers that incorporate thermal protection or fused 
transformer primary windings to prevent transformer failure due to 
overcurrent.
 
RF Device Placement: RF dimmers, switches, keypads and shades/
drapes must be located within 30 ft (9 m) of an RF signal repeater. For 
systems without an RF signal repeater, all RF dimmers, switches, keypads 
and shades/drapes must be located within 30 ft (9 m) of each other. 
Remote dimmers and switches are not required to be within a specific 
range.
Important Notes
Local Operation
Pressing the Tapswitch on the Lamp Dimmer will alternately turn the lights  
ON and OFF. 
The ON level will be the level previously set using the Dimming Rocker to the  
right of the Tapswitch. The LED that is glowing slightly brighter than the others  
indicates the level to which the lights will turn ON. Press and hold the top or  
bottom of the Dimming Rocker to raise or lower the light level. Double-tapping 
the Tapswitch will turn the lights ON to full. Pressing and holding the Tapswitch 
for 1/2 second (while ON) activates a 10-second long fade-to-off. 
Note: Refer to the system Setup Guide for additional troubleshooting suggestions.
Lamp Dimmer