JVC KENWOOD Corporation 463500 用户手册

下载
页码 1
KPG-36X    KPG-46X 
USB PROGRAMMING INTERFACE CABLE
INSTRUCTION MANUAL
© B5A-0568-00 (M)
One or more of the following statements may be applicable to this equipment.
FCC WARNING
This equipment generates or uses radio frequency energy.  Changes or 
modifi cations to this equipment may cause harmful interference unless 
the modifi cations are expressly approved in the Instruction manual.  The 
user could lose the authority to operate this equipment if an unauthorized 
change or modifi cation is made.
INFORMATION TO THE DIGITAL DEVICE USER REQUIRED BY THE FCC
This equipment has been tested and found to comply with the limits for a 
Class B digital device, pursuant to Part 15 of the FCC Rules.  These limits 
are designed to provide reasonable protection against harmful interference 
in a residential installation.
This equipment generates, uses and can generate radio frequency 
energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications.  However, 
there is no guarantee that the interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio 
or television reception, which can be determined by disconnecting and 
then reconnecting the cable, the user is encouraged to try to correct the 
interference by one or more of the following measures:
•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and receiver.
•  Connect the equipment to an outlet on a circuit different from that to 
which the receiver is connected.
•  Consult the dealer for technical assistance.
Information on Disposal of Old Electrical and Electronic Equipment (applicable 
for EU countries that have adopted separate waste collection systems)
Products and batteries with the symbol (crossed-out wheeled bin) cannot be 
disposed as household waste.
Old electrical and electronic equipment and batteries should be recycled at a 
facility capable of handling these items and their waste byproducts.
Contact your local authority for details in locating a recycle facility nearest to you.
Proper recycling and waste disposal will help conserve resources whilst 
preventing detrimental effects on our health and the environment.
Notice: The sign “Pb” below the symbol for batteries indicates that this battery 
contains lead.
SUPPLIED ITEMS
• 
USB programming interface cable (USB 2.0 Full speed (12 Mb/s) 
compliant)  <cable length: 4.92 ft/ 1.5 m>
• 
CD (with driver software)
• 
Instruction manual (B5A-0568-XX)
OPERATING SYSTEM
Windows Vista (32/ 64-bit)/ Windows 7 (32/ 64-bit)/ Windows 8 
(32/ 64-bit)/ Windows 8.1 (32/ 64-bit)
INSTALLING THE DRIVER
When using the KPG-36X/ 46X for the fi rst time, install the 
supplied KPG-36X/ 46X driver.
ATTENTION:  
♦   For Fpro software, use version 6.00 or later.
♦   For KFL software, use version 1.10 or later.
♦   Depending on the usage condition of the USB apparatus, saved 
content may be lost.  KENWOOD does not take responsibility for 
damages or lost content.
1  Turn on the computer, then insert the supplied CD into the 
CD-ROM drive of the computer. 
2  When using KPG-36X/ 46X for NX-5200/ NX-5300/ 
NX-5400/ NX-5700/ NX-5800, the USB driver whose 
transfer rate is faster than the UART driver or the current 
UART driver can be selected. 
Refer to the service manual for other models, and if there are 
not any specifi c descriptions, select UART driver.
 
If installing the UART driver:
Double-click  the CP210xVCP  folder .
Double-Click the [CP210xVCPInstaller_x64.exe] or 
[CP210xVCPInstaller_x86.exe]fi le. When installation 
Wizard starts, click [Next>].
If installing the USB driver:
 
Double click  [Kenwood_Communications_Product_
USB_Port_Type1]
 folder. Double click the [Kenwood_
Type_1_USB_Driver_32bit.exe]
  or [Kenwood_Type_1_
USB_Driver_64bit.exe]
 fi le. When the Installation Wizard 
starts, click [Next>] .
• 
Concerning  the 64-bit version or 32-bit version, you 
should check the PC in advance.
3  Read through the licensing agreement. If you consent to the 
terms of the agreement, check the "I accept this agreement" 
box, then click [Next>].
• 
Start the installation.
4  When the driver fi nishes copying to the computer, click the 
[Finish].
Note: 
♦   The KPG-36X/ 46X is installed as a virtual port driver.
♦   The KPG-36X/ 46X does not support programs other than those 
used for KENWOOD transceivers.
♦   If the driver cannot be installed or if, having installed the driver 
and restarted your computer, the driver cannot be found or the 
operation does not stabilize, try changing the USB port to that 
which you have connected the KPG-36X/ 46X.  Additionally, try 
removing other equipment attached to the computer USB ports.
♦   Access the following URL for the driver download information:
http://www.kenwood.com/usb-com/
CONNECTING TO A COMPUTER AND TRANSCEIVER
Connect one of the KPG-36X/ 46X USB connectors to the USB 
port of the PC, and the other connector to the transceiver.
Note: 
 
♦  Connect the KPG-36X/ 46X directly to the transceiver and the PC 
(or USB HUB).
♦  Do not connect the KPG-36X/ 46X other than PC (or USB HUB).
  It causes malfunction of the KPG-36X/ 46X and the transceiver.
ABOUT SELECTING USB/ UART
For using USB (Up to 12 Mb/s USB Speed), Slide the SW of 
KPG-36X/ 46X to USB.
For using UART (RS-232C), Slide the SW of KPG-36X/ 46X to 
UART.
CONFIRMING THE INSTALLATION
Connect the KPG-36X/ 46X to a USB port, In the 
“Device Manager”, open the “Port(COM and LPT)”.  
In case of the SW position of UART, If “Silicon Labs CP210x 
USB to UART Bridge(COMx)” appears, installation is complete.
In case of the SW position of USB, “KENWOOD Type1(COMx)” 
appears, installation is complete.
UNINSTALLING THE DRIVER
In the “Program Installation and Deletion” screen, uninstall the 
following item:
“Windows Driver Package - Silicon Laboratories (silabenm) 
Ports (mm/dd/yyyy x.x.x.x.)”
“Windows Driver Package - JVC KENWOOD Corporation Radio 
USB Port Type 1 Driver (mm/dd/yyyy x.x.x.x.)”
COPYRIGHTS
•   Windows
®
 and Windows Vista
®
 are registered trademark of 
Microsoft Corporation in the United States and/or other countries.
•   Other product and company names mentioned herein may be 
the trademarks of their respective owners.
Authorized Representative in Europe:
Amsterdamseweg 37, 1422 AC Uithoorn, The Netherlands
Manufacturer:
1-16-2 Hakusan, Midori-ku, Yokohama-shi, Kanagawa, 226-8525 Japan