Ref. No: 307010E
Mechanical Installation
2.4 Mounting the Cone Antenna
1
Make sure that the following
parts are available when
installing the gauge.
2
Mount the flange on top of the
cone plate.
Secure the flange with the
locking nut and make sure
that the nut is fitted tightly to
the flange.
Make sure that the PTFE Seal
and the O-rings are not dam-
aged. Damaged PTFE Seal or
O-ring may cause gas leakage
from pressurized tanks.
!
Caution
Make sure that the bottom
side of the flange is flat and
all parts are clean and dry in
order to avoid gas leakage
from pressurized tanks.
!
Caution
Transmitter
Locking nut
Flange
Gasket
Nuts and bolts
Union nut
Set screw
O-ring
Seal
Locking nut
Flange
Note!
No gasket here.
Cone plate
Cone antenna