Rosemount Tank Radar AB REX 用户手册

下载
页码 73
Saab TankRadar L/2
27
US Version. Seventh edition, June 1995
Installation Manual
6.5
Installation Data for FCU 2160
Ambient operating temperature:
-40
°
C to +65
°
C
(-40
°
F to +149
°
F)
Power Supply
115 or 230 VAC, +10% to -15%,
50-60 Hz, max. 80 W
Group bus interface
TRL/2 Bus, RS-232 or RS-485
Field bus interface
TRL/2 Bus. Max 16 units on
one port
Ambient operating temperature:
-40
°
C to +65
°
C
(-40
°
F to +149
°
F)
Explosion protection
None
Number of RTGs and/or Independent DAUs Max. 32 RTGs and
32 DAUs
Cable Outputs
Ground
Connection
Saab Tank Control
TankRadar L/2
Serial no:
UI:
A division of Saab Marine Electronics AB
Field Connection Unit              Type FCU 2160
MADE IN SWEDEN
0.23 m
0.28 m
Figure 6.4. The Field Communication Unit.