10.2.5 Socket Requirements
When using a Ø 20" socket the height of the socket must not ex-
ceed 0.6 m.
If a socket with a larger diameter is used then the height can also
be larger. In this case there must be a free passage for the radar
beam within a 5
°
 angle from the edge of the Parabolic Reflector to
the bottom end of the socket. See figure 10.7.
Note:
 The distance from the top of the customer’s flange to the maximum
product surface should not be less than 1.0 m. The highest accuracy
cannot be maintained at distances less than 1.0 m.
5
°
 Min
5
°
 Min
Vertical
Plumb Line
Ø 455 mm
Larger than
Ø 20"
Socket
height
max
0.6 m
Min 1.0 m
to  product
surface
Max
100 mm
Bottom of flange
Figure 10.7 shows the requirements on the socket to RTG 2930.