1.0  Overview
The RF835 TriTech® detector uses passive infrared technology, Micro-
wave technology, and artificial intelligence to detect motion and pro-
vides freedom from false alarms.  When motion is detected the unit
sends an alarm signal to the control panel.
2.0  Specifications
General
Power supplied by four 1.5V AA Alkaline Batteries.
Typical current draw is 100 micro-amps with LED disabled.
Typical battery life is two to three years (has not been verified by
Underwriters Laboratories).
Operating temperature range of +32°F to +120°F (0°C to +49°C)
Microwave Frequency: 10.525 Ghz (U.L. Listed)
RF Transmit Frequency: 304.00 MHz
Options: Low Profile Swivel Mount Bracket (use of this bracket may
reduce range and dead zone areas).
3.0 Installation
TriTech Motion Sensor
Coverage area 35 ft. by 35 ft. (10.7 m by 10.7 m)
Internal coverage pointability -6°  to -10° Vertical and ±10° Horizontal.
Masking kit provided to block portions of coverage area.
Field selectable sensitivity options of Standard and Intermediate.
Three minute transmitter lockout time after alarm extends battery life.
Timed Walk Test Mode automatically disables LED after setup to extend
battery life.
Cover activated Tamper indication. Optional wall activated Tamper is
included.
Pet Immunity capabilities have not been verified by UL.
RF Transmitter
Integral RF transmitter capable of transmitting 500 feet open air.  (Actual
acceptable transmitter range should be verified for each installation).
Transmits low battery report (trouble) to the control panel.
Transmits tamper
Transmits supervisory signal to the control panel every 64 minutes.
3.1  Open the cover
3.2  Open base
3.3  REMOVE BATTERY PLUG
3.5 Observe the Pet Immunity mounting recommendations
6.5 Ft
(2 M)
Mount the detector 6 1/2 feet
(2 meters) above the floor
NO
Don't
point
at
stairs
Don't
point
where
pets
can
climb
NO
3.6 Avoid:
Hot or cold air
directed onto
sensor
Direct or
reflected
sunlight
Moving objects
Moisture
3.7  Observe the Pet Immune  Area
3.8 Observe Receiver Range
Upper
areas
are
not
pet
immune
Pet Immune Area
OK
NO
500’ max
(300 meters)
Panel Receiver
Insert four (4)
size AA Alkaline
batteries in the
battery holder per
the guides imprinted
on the holder
Notches
Insert
screwdriver
into notches
and gently
twist to open
3.4  Select a mount-
ing location
DO NOT MOUNT
OUTDOORS
PRELIMINARY