Digital Security Controls Ltd. 00NB9001 用户手册

下载
页码 34
26
Table2: Contact ID Zone Alarm/Restoral Event 
Codes (as per ADEMCO):
Program any of these codes for zone alarms/restorals when using the 
standard (non-automatic) Contact ID reporting format.
Table 3: SIA Format Automatic Zone 
Alarm/Restoral Codes
Section #
Reporting Code
Code Sent When...
Dialer 
Direction*
Automatic 
Contact ID 
Codes
SIA Auto Rep 
Codes**
[349] to 
[350]
AC Line Trouble/Rest.
AC power to system is disconnected or interrupted/AC 
power restored (Both codes follow AC Failure Comm. 
Delay.)
MA/R
(3) A1
AT-00/AR-00
[349] to 
[350]
Fire Trouble/Rest.
a trouble occurs/restores on a fire zone
MA/R
(3) 73
FT-00/FJ-00
[349] to 
[350]
Gen System Trouble/Rest.
“Service Required” trouble occurs (view troubles using 
[*][2])/trouble restored
MA/R
(3) AA
YX-00/YZ-00
[351]
Line 1 or 2 FTC Restoral
system has restored communications to central station on 
line 1 or 2 (after FTC)
MA/R
(3) 54
YK-00
[351]
Event Buffer is 75% Full
event buffer is almost full since last upload
MA/R
(6) 23
JL-00
[351]
DLS Lead In
downloading session start
MA/R
(4) 11
RB-00
[351]
DLS Lead Out
downloading session complete
MA/R
(4) 12
RS-00
[351]
Zone Fault/Rest.
one or more zones have faults/restored
MA/R
(3) 72
UT-ZZ/UJ-ZZ
[351]
Delinquency
programmed amount of time (days or hours) for delin-
quency has expired without zone activity, or without system 
being armed
MA/R
(4) 54***
CD-00
[353]
Wireless Device Low Battery 
Trouble/Rest.
wireless zones, panic pendants, handheld keypads, wireless 
keys have low battery/all low batteries restored
MA/R
(3) 84
XT-00/XR-00
XT-ZZ/XR-ZZ****
[352]
Periodic Test
periodic system test transmission  
T
(6) A2
RP-00
[352]
System Test
[*][6] bell/communications test
T
(6) A1
RX-00
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
** UU = user number (user01-42); ZZ = zone number (01-32)
***Program the “Fail to close” event code [(4)54] to report either closing or activity delinquency. Make sure your central station is aware of the applica-
tion of this reporting code.
****Zones are identified, panic pendants, wireless keys, and handheld keypads are not.
Medical Alarms 
(1)34  Entry / Exit
(1)AA  Medical
(1)35  Day / Night
(1)A1  Pendant Transmitter
(1)36  Outdoor
(1)A2  Fail to Report In
(1)37  Tamper
Fire Alarms
(1)38  Near Alarm
(1)1A  Fire Alarm
General Alarms
(1)11  Smoke
(1)4A  General Alarm
(1)12  Combustion
(1)43  Exp. module failure
(1)13  Water Flow
(1)44  Sensor tamper
(1)14  Heat
(1)45  Module Tamper
(1)15  Pull Station
(1)4A  Cross Zone Police Code
(1)16  Duct
24 Hour Non-Burglary
(1)17  Flame
(1)5A  24 Hour non-Burg
(1)18  Near Alarm
(1)51  Gas detected
Panic Alarms
(1)52  Refrigeration
(1)2A  Panic
(1)53  Loss of Heat
(1)21  Duress
(1)54  Water Leakage
(1)22  Silent
(1)55  Foil Break
(1)23  Audible 
(1)56  Day Trouble
Burglar Alarms
(1)57  Low bottled Gas level
(1)3A  Burglary
(1)58  High Temp
(1)31  Perimeter
(1)59  Low Temp
(1)32  Interior
(1)61  Loss of Air Flow
(1)33  24 Hour
Zone Definition
SIA Auto Rep 
Codes*
Zone Alm/Rest.
Delay, Instant, Interior, Delay Stay/
Away, Interior Stay/Away, 24Hr 
Burg.
BA-ZZ/BH-ZZ
24Hr Supervisory Buzzer
UA-ZZ/UH-ZZ
24Hr Sprinkler
SA-ZZ/SH-ZZ
24Hr Gas
GA-ZZ/GH-ZZ
24Hr Heat
KA-ZZ/KH-ZZ
24Hr Medical
MA-ZZ/MH-ZZ
24Hr Emergency (non-medical)
QA-ZZ/QH-ZZ
24Hr Waterflow
WA-ZZ/WH-ZZ
24Hr Freeze
ZA-ZZ/ZH-ZZ
24Hr Holdup
HA-ZZ/HH-ZZ
24Hr Panic
PA-ZZ/PH-ZZ
Latching 24Hr 
BA-ZZ/BH-ZZ
* ZZ = zones 01-32