Digital Security Controls Ltd. 01NB9010 用户手册

下载
页码 68
S e c t i o n   2. 2:  C h an g i n g   H o w   t h e   N T 90 1 0   W o r k s   F o r  U s e r s
2 5
Opening After Alarm Bell Ringback . . . . . . . . . . . . . . . . .  Section [381], Option [2]
Closing Confirmation. . . . . . . . . . . . . . . . . . . . . . . . . . . .  Section [381], Option [4]
AC/DC Inhibit Arming  . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [701], Option [3]
2.2.6
Automatic 
Arming
You can program the system to automatically arm at a specific time every day. 
Three items must be enabled in order to activate the auto arming function:
1. The correct time of day must be programmed. For instructions on programming 
the time and date, see the NT9010 User’s Guide (“Setting the Time and Date”).
2. Enter [✱][6][Master Code][2] to enable (three keypad beeps) or disable (one 
long beep) the auto-arm feature.
3. Program the auto-arm time using the [✱][6][Master Code][3] command.
When the internal system clock matches the programmed auto arm time, the sys-
tem will check its status. If the system is armed, the NT9010 will do nothing until 
the programmed auto-arm time for the next day, when it will check again.
If the system is disarmed at the auto-arm time, the NT9010 control unit will sound 
the keypad buzzer for one minute. This is the auto arm pre-alert period.
If the Bell Squawk During Auto Arm option is enabled, the bell will squawk 
while the system is auto-arming in order to notify anyone on the premises that the 
system is being armed.
If a valid access code is entered during the auto arm pre-alert period, automatic 
arming will be cancelled. If automatic arming is cancelled by a user, the system will 
send the Auto Arm Reporting Code to the central station.
NOTE:
The Maintenance code cannot be used to cancel automatic arming.
If no code is entered during the auto-arm prealert, the system will auto-arm. If a 
zone is violated when the system arms, the system will transmit a Partial Closing 
Reporting Code
 (if programmed), to indicate the system was not secure. If the 
zone is restored, the NT9010 will arm the zone and add it back into the system.
Program Time and Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . [✱][6][Master Code][1]
Enable Auto Arming  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [✱][6][Master Code][2]
Program Auto Arm Time . . . . . . . . . . . . . . . . . . . . . . . . . . . [✱][6][Master Code][3]
Partial Closing Reporting Code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [343]
Auto Arm Cancellation Reporting Code . . . . . . . . . . . . . . . . . . . . . . . Section [348]
Bell Squawk During Auto Arm . . . . . . . . . . . . . . . . . . . . .  Section [014], Option [2]
2.2.7
Entry and 
Exit Delay 
Options
Upon arming, the system will begin the exit delay. If Audible Exit Delay is enabled 
the keypad will beep every second until the exit delay expires. The keypad will beep 
rapidly for the last 10 seconds of exit delay to warn the user the system is about to 
arm.
Users can restart the exit delay one time while it is counting down by pressing the 
Away key. The system will not log the user who re-started the exit delay, unless the 
Quick Arming Disabled/Function Keys Require Code option is turned on (sec-
tion [015], option [4]).