Digital Security Controls Ltd. 18LE2077 用户手册

下载
页码 51
30
[214] Cellular Receiver 2 Port
Default (0BF5/3061)
This Section defines the port of Cellular Receiver 2. Change the value of this port when your
installation is located behind a firewall and must be assigned a particular port number, as
determined by your central station system administrator. Valid range: 0000 - FFFF.
NOTE: Do not program Cellular Receiver 1 and Cellular Receiver 2 to communicate to the same
receiver.
[215] Cellular Receiver 2 APN
Default (  )
The APN determines the Cellular network that the Communicator will connect to. This
information is available from your network carrier. Program this Section with up to 32 ASCII
characters.
NOTE: When a SIM card with a custom APN is used, the unit will not have access to the internet.
DLS and remote flash can still be done if Section [221] is programmed with a valid
Public APN.
[216] Cellular Receiver 2 Domain Name
Default (  )
i
Programming this Section is not permitted on a UL/ULC listed system.
Enter the Cellular Receiver 2 Domain Name with up to 32 ASCII characters.
C
ELLULAR
 O
PTIONS
[221] Cellular Public Access Point Name
Default (  )
When the Communicator is operating on a private APN, use this Section to select a public APN
for DLS and Remote Firmware Update. This information is available from your network carrier.
The APN identifies the public Cellular network that the Communicator will connect to.
[222] Cellular Login User Name
Default (  )
Some network carriers require you to provide login credentials when connecting to an APN.
Program your login User Name in this Section. Format is up to 32 ASCII characters.
NOTE: This Section is not accessible via SCW keypad programming.
[223] Cellular Login Password
Default (  )
Some network carriers require you to provide login credentials when connecting to an APN.
Program your login Password in this Section.
Format is up to 32 ASCII characters.
[224] Cellular Test Transmission Time of Day
Default (9999)
Enter a 4 digit value using the 24-hour clock format (HHMM) to set the test transmission time of
day. Valid range: 00-23 for the hours (HH) and 00-59 for the minutes (MM).
NOTE: To disable the test transmission time of day enter 9999 or FFFF in this Section.
The internal date and time will be automatically programmed by the primary receiver only.
[225] Cellular Test Transmission Cycle 
Default (000000)
This value represents the interval in between test transmissions in minutes. Valid range:
000000 - 999999 minutes. Once the unit has sent the initial periodic test transmission, all
future test transmissions will be offset by the programmed number of minutes. See Sections
[026] - [029].
Table 14: Cellular Test Transmission Interval
Test Transmission Interval
Daily
Weekly
Monthly
Programmed Minutes
001440
010080
043200