1 DESCRIPTION 
This
 section provides a complete description of the Remote Interface Unit (RIU).  
1.1  Primary Functions and Components 
The
  RIU,  shown  in  Figure  1,  serves  as  the  interfacing  unit  between  a  remote  BTS  and  the 
Digivance
 DHU. The RIU provides the following basic functions:  
• 
RF
 interface to the BTS (through donor antenna) and DHU 
• 
Gain
 adjustments to the forward and reverse path RF signal 
• 
Duplexing
 of the forward and reverse path RF signals 
• 
Alarm
 reporting to an external alarm system 
16650-A
FRONT PANEL
CABLE MANAGEMENT
TRAY
MOUNTING
BRACKET
(BOTH SIDES)
3.5 INCHES
(89 mm)
11.4 INCHES
(290 mm)
3.9 INCHES
(99 mm)
17.2 INCHES
(437 mm)
13.6 INCHES
(345 mm)
 
Figure 1. Remote Interface Unit 
A
 remote interface between the DHU and the BTS (cell site base station) via a donor antenna 
requires
 specific RF input and output signal levels at the DHU and antenna. The correct levels 
at
 the DHU and antenna can be provided using the RIU. The RIU provides adjustable gain in 
both
 the RF forward and reverse paths. The RIU connects to a directional antenna through a 
duplexer
 which provides separate forward and reverse path connections for the DHU. In the 
forward
 path (downlink), the RIU provides the recommended composite maximum RF input 
signal
 level at the DHU which is –20 dBm. When the level of the RF input signal at the DHU 
is
 –20 dBm, the level of the RF output signal at the DRU is +13 dBm which is the maximum 
allowed.