ADC Telecommunications Inc. FWM1901A 用户手册

下载
页码 23
© ip.access Ltd 
 
COMPANY CONFIDENTIAL 
CENG0133_C_Customer_Safety_and 
_Regulatory_Information.doc 
- 14 -
 
 
PSU’s supplied by ip.access must not be used for powering any other 
equipment (unless carried out in a manner having prior written approval from IP 
Access). 
 
TIB ports on the NanoBTS may only be connected with ip.access supplied 
cables with part numbers 139-040, 139-041, 139-042, 139-043 or 165-076. 
 
Fitting external antenna or antenna cabling to the BTS invalidates the type 
approval, CE marking and UL listing referred to herein (unless carried out in a 
manner having prior written approval from IP Access). 
 
Maximum cable length from the Ethernet Hub, Switch or PSU is limited to 
100m. 
 
5.2  NanoBTS  - Handbook - Parts required for each nanoBTS 
• 
WALL FIXINGS: These are not normally provided as part of the 
NanoBTS but should be suitable for the wall material and weight of 
the NanoBTS (2.7kg).  Suggested materials are 4 x 30mm no.10 
woodscrews or M5 bolts and wall plugs (if required).  
• 
PSU. 
• 
NanoBTS complete with mounting bracket. 
• 
RJ45-RJ45 connecting leads 
 
 
5.3  NanoBTS - Handbook - Provision of Power to the nanoBTS 
Power for the NanoBTS may be inserted at either the RJ45 outlet or at the 
output of the last Ethernet switch/hub/router etc. see figure below.