ADC Telecommunications Inc. FWM1901A 用户手册
© ip.access Ltd
COMPANY CONFIDENTIAL
CENG0133_C_Customer_Safety_and
_Regulatory_Information.doc
- 14 -
PSU’s supplied by ip.access must not be used for powering any other
equipment (unless carried out in a manner having prior written approval from IP
Access).
TIB ports on the NanoBTS may only be connected with ip.access supplied
cables with part numbers 139-040, 139-041, 139-042, 139-043 or 165-076.
Fitting external antenna or antenna cabling to the BTS invalidates the type
approval, CE marking and UL listing referred to herein (unless carried out in a
manner having prior written approval from IP Access).
Maximum cable length from the Ethernet Hub, Switch or PSU is limited to
100m.
5.2 NanoBTS - Handbook - Parts required for each nanoBTS
•
WALL FIXINGS: These are not normally provided as part of the
NanoBTS but should be suitable for the wall material and weight of
the NanoBTS (2.7kg). Suggested materials are 4 x 30mm no.10
woodscrews or M5 bolts and wall plugs (if required).
•
PSU.
•
NanoBTS complete with mounting bracket.
•
RJ45-RJ45 connecting leads
5.3 NanoBTS - Handbook - Provision of Power to the nanoBTS
Power for the NanoBTS may be inserted at either the RJ45 outlet or at the
output of the last Ethernet switch/hub/router etc. see figure below.