ADC Telecommunications Inc. PRSM074C 用户手册

下载
页码 138
Managing Remote Units
Page 242
FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc
ADCP-77-073
  • Issue 2 • 11/2009
4
4
If any status indicator in the 
Major Alarms
 or 
Minor Alarms
 table is red or yellow, 
refer to the following list:
Remote  Capacity
—Number of slots for RF Modules in the remote. Each RF 
Module comprises up to two Classic DARTS or Single SuperDARTs or one Dual 
SuperDART.
Remote  Temperature
 field—Currently detected internal temperature of the 
Remote (measured near the SeRF board).
Host  Lost  Fault
 status indicator—Red indicates Remote has lost contact with 
Host. 
Remote  Lost  Fault
 status indicator—Red indicates that the Host is unable to 
communicate with the Remote. 
AC Power Supply Fault
 status indicator—Red indicates Remote power supply has 
failed.
Over Temperature Fault
 status indicator—Red indicates internal temperature in 
Remote is over its functional operating limit. Fault threshold is 
84°C
.
Fan Under Speed Fault
—Red indicates that the speed of the Remote fan is not 
high enough for the internal functional temperature of the Remote.
Under  Temperature  Fault
 status indicator—Yellow indicates that the internal 
temperature within the Remote is under the operating limit. Fault threshold is 
-40°C
.
Fan Over Speed Fault
—Yellow indicates that the Remote fan is not necessary for 
the current internal temperature of the Remote, but the fan is spinning (Minor 
alarm).
Open Door Fault
—Yellow status indicator for this Minor alarm, which indicates 
that the door to the Remote is open.
Apply
 button—When clicked, causes Remote Name entry to be applied
Refresh
 button—When clicked, causes page to be reloaded from Host
DART ID 8
RF Slot 4
DART ID 7
DART ID 6
RF Slot 3
DART ID 5
DART ID 4
RF Slot 2
DART ID 3
DART ID 2
RF Slot 1
DART ID 1
SERF Board