Configuring the Multiprotocol Rail Reader
8-17
Flow control scheme (none, software, hardware) 
The default serial port configuration for each of these three parameters is as follows:
9600 baud, 8 data bits, 1 stop bit, no parity
Basic communications protocol
Software flow control (XON/XOFF)
You can change these parameters in data mode and command mode operation by issu-
ing commands with the host device. Use the following procedures to set serial port 
communications parameters using the terminal emulation program.
Port Configuration Parameters
Use this procedure to set port configuration parameters using the terminal emulation 
program. Consult sections 
" through 
.
To set baud rate 
1.
Ensure that the host computer is in command mode.
2.
Enter command #100N and press ENTER.
To set stop bits
1.
Ensure that the host computer is in command mode.
2.
Enter command #101N and press ENTER.
To set parity
1.
Ensure that the host computer is in command mode.
2.
Enter command #102N and press ENTER.
Communications Protocol
Use the following procedures to set communications protocol. Consult sections 
 through 
 for more information.
Caution
Do not switch to ECP (command #611) unless the host is prepared to acknowledge 
each reader transmission.
To select a communications protocol
1.
Ensure that the host computer is in command mode.
2.
Enter command #610 to select basic protocol (factory default) or command 
#611
 to select ECP and press ENTER.