Everspring Industry Co Ltd HSM02 用户手册

下载
页码 6
HSM02 
DOOR/WINDOW DETECTOR 
 
The Door/Window Detector is a Z-Wave
TM
 enabled device and is fully compatible 
with any Z-Wave
TM
 enabled network. Z-Wave
TM
 enabled devices displaying the 
Z-Wave
TM
 logo can also be used with it regardless of the manufacturer, and ours 
can also be used in other manufacturer’s Z-Wave
TM
 enabled networks.  Inclusion 
of this Door/Window Detector on other manufacturer’s Wireless Controller menu 
allows remote turn-on of connected modules and their connected lighting when the 
Detector is triggered. 
LED
TEMPER
SWITCH
BATTERY
BATTERY
MYLAR
FIXED
SCREW
 
 
Include to or Exclude from a Z-Wave
TM
 Network   
 
In the front casing, there is a tamper switch which is used to carry out inclusion, 
exclusion or reset.  When power is first applied, its LED flashes on and off 
alternately and repeatedly at 2-second intervals.  It implies that it has not been 
assigned a node ID and cannot work with Z-Wave enabled devices.    Please get 
familiar with the terms below before starting the operations.     
 
Function 
Description 
Inclusion   
Add a Z-Wave enabled device (e.g. Detector) to Z-Wave network. 
Exclusion   
Delete a Z-Wave enabled device (e.g. Detector) from the network. 
Association    After inclusion, you have to define the relationship between devices. 
Trough association, device can be assigned as master/slave, and specify 
which slave is going to be controlled by which master. 
Reset 
Restore Detector to factory default. 
 
The table below lists an operation summary of basic Z-Wave functions.  Please 
refer to the instructions for your Z-Wave
TM
 Certificated Primary Controller to access 
the setup function, and to include/exclude/associate devices.   
 
Function Description 
LED 
Indication 
No node ID 
The Z-Wave Controller does not allocate 
a node ID to the unit. 
2-second on, 2-second 
off 
Inclusion 
1.  Have Z-Wave Controller entered 
inclusion mode. 
 
2.    Pressing tamper switch three times 
within 1.5 second will enter inclusion 
mode. 
Exclusion 
1.  Have Z-Wave Controller entered 
exclusion mode. 
LED lights up once 
whenever tamper switch 
is pressed once. 
2.  Pressing tamper switch three times 
within 1.5 second will enter 
exclusion mode. 
Reset 
1.  Press tamper switch three times 
within 1.5 second. 
 
2.  Within 1 second, press and hold the 
tamper switch until LED is off. 
LED keeps on before 
reset function has been 
completed. 
3.  IDs are excluded and all of preset 
value will be reset to factory default.
2-second on, 2-second 
off 
Association 
1.    Have Z-Wave Controller entered 
association mode. 
 
2.    When pressing tamper switch three 
times within 1.5 second, the unit will 
emit the NIF which implies that the 
unit has entered association mode. 
 
Ú
Including a node ID allocated by Z-Wave Controller means inclusion.    Excluding a node 
ID allocated by Z-Wave Controller means exclusion. 
Ú
Failed or success in including/excluding the node ID can be viewed from the Z-Wave 
Controller.