Balogh T A G Inc 30RMOL81 用户手册

下载
页码 20
MOL81 485 1312/MOL81 485 1337
 
MOL81 485 1312-MOL81 485 1337-UM-1.4-EN
 
 
13/20 
Command: 
01 CF 00 49 00 01 C1 C2 
 
Reply:   
01 CF 02 B1 23 C1 C2   
(MOL1312, version 1.23) 
where CF = 3 or 4 
 
6.6  Command: Read Device Status 
This command will read the device status. The reply contains one byte status
Command: 
01 CF 00 40 00 01 C1 C2 
 
Reply:   
01 CF 02 00 ST C1 C2 
where CF = 3 or 4 
ST has the following structure: 
125 
VA 
NC 
AC 
EE 
 
EE: EEPROM OK, active 1. 
AC: a tag is present, active 1. 
NC: new code available, active 1. 
VA: a new code is valid. 
125: 125 kHz emitter state, active 1. 
 
The following table describes the conditions of activation/deactivation of this flags, on the MOL81-1312 and the 
MOL81-1337: 
 
 
Flag 
125 
MOL81-1312:
 
The 125 KHz emitter is operational.
 
 
MOL81-1337: 
The MOL81 is installed on a metal plate and 
the 125 KHz emitter is operational. 
MOL81-1312:
 
The 125 KHz emitter is not operational. 
 
MOL81-1337:
 
The MOL81 is not installed on a metal plate or 
the 125 KHz emitter is not operational. 
VA 
The  MOL81  has  read  the  same  code 
successfully twice 
The  MOL81  has  read  one  new  code 
successfully,  not  consolidated  by  a  second 
reading. 
NC 
Set when VA is set (after 2 properly readings)  Reset  when  a  new  code  has  been  read 
successfully  but  not  consolidated  by  a  new 
reading or, 
A  Read  Last  Tag  Code  command  was 
received. 
AC 
Set when a properly reading has been done. 
Reset  when  no  properly  reading  has  been 
done. 
EE 
The  configuration  parameter  has  been 
modified with a “Write Parameters” command 
(see §
6.7
The non volatile memory is corrupted
 
 
 
Examples: 
Command: 
01 03 00 40 00 01 85 DE 
 
Reply:   
01 03 02 00 89 78 24   
(125 kHz active, A new code is valid, EEPROM ok)