Balogh T A G Inc 30RMOL81 用户手册

下载
页码 20
MOL81 485 1312/MOL81 485 1337
 
MOL81 485 1312-MOL81 485 1337-UM-1.4-EN
 
 
18/20 
9  MAINTENANCE 
9.1  Regular maintenance 
 
The MOL81 requires no regular maintenance. 
 
The unit should be regularly cleaned to avoid accumulation of dirt. 
 
The unit should be regularly checked for: 
cracks in the case 
broken mounting points 
missing mounting screws 
screws tightened with specified torque 
connectors correctly locked 
 
MOL81 operation should be regularly checked according to the above procedure. 
 
9.2  Device replacement 
 
If the MOL81 needs to be replaced, the procedure is as follows: 
 
Turn the knurled ring of the plug anti-clockwise (1/3 turn) to unlock the connectors 
Remove the 4 mounting screws and dismount the unit, taking care to record the orientation 
Place the new MOL81 in the same position, insert the 4 mounting screws and tighten to the specified 
torque 
Insert connector and turn the knurled ring clockwise (1/3 turn) until locked. 
 
Check for correct operation according to the procedure above. 
 
 
9.3  Recycling 
 
All  decommissioned  units  must  be  returned  to  BALOGH  SA  for  appropriate  recycling  according  to  directive 
D3E.