Balogh T A G Inc 30RMOL81 用户手册

下载
页码 20
MOL81 485 1312/MOL81 485 1337
 
MOL81 485 1312-MOL81 485 1337-UM-1.4-EN
 
 
5/20 
2.2  Basic operation 
After a reset or a power-up, the MOL81 is ready for use, no other setting up is necessary. When a valid tag is 
detected, its identifier can be read with a MODBUS command.  
Commands can be sent to the device at any time, for control and for special setups. These commands may be 
acknowledged  (ACK  or  NAK)  and  may  receive  a  response.  No  asynchronous  commands  are  sent  by  the 
MOL81. 
2.3  Power 
The  MOL81  is  powered  with  24Vdc,  the  voltage  range  acceptable  for  correct  operation  is  21Vdc  to  29Vdc 
(including any ripples). Typical current drawn at 24Vdc is 600mA, with a maximum of 1A. The power module is 
protected against polarity inversions. 
Any changes in settings are memorised, so that after a reset the same settings are used as before the previous 
power-down. In particular, if the 125 kHz emitter was deactivated before power-down, it will still be deactivated 
after power-up. 
Conversely, if the 125 kHz emitter was activated after power-up, it will also be activated at the next power-up, if 
no configuration changes have been made. In this case, the activation time for the 125 kHz emitter is roughly 
250 ms.