Rosslare Enterprises Ltd AYCF6X 用户手册

下载
页码 66
Technical Specifications 
AYC-F/G/M60 Series Installation and Programming Manual 
11 
2.
 
Technical Specifications 
Electrical Characteristics 
Power Supply Type 
Linear (recommended) 
Operating Voltage Range 
5–16 VDC (when used as a controller, 
provided by the secured intelligent power 
supply) 
Input current standby (12 
VDC) 
100 mA 
Input Current Max (16 VDC)  140 mA 
LED Control Input 
Dry contact N.O. 
Tamper Output 
Open collector, active low, 32 mA max sink 
current  
Cable Distance to Host 
Controller 
Up to 150 m (500 ft) using an 18 AWG cable 
Max. Proximity Card Read 
Range* 
60 mm (2.4 in.) 
Proximity Card Modulation  Rosslare proximity/HID Prox at 125 kHz 
Proximity Card Compatibility  Rosslare proximity/HID Prox cards 
Card Transmit Format 
(Reader) 
Rosslare proximity cards: Wiegand 26-Bit, or 
Clock & Data 
HID Prox cards: According to card type 
Keypad Transmit Format 
(Reader) 
Programmable PIN code formats (see Section 
LED Indicators 
Two tri-colored LEDs 
Communication 
Data1/C1, Data0/C2–open collector, 5 V 
termination 
*  Measured using a Rosslare proximity card or equivalent. Range also 
depends on electrical environment and proximity to metal.