Rosslare Enterprises Ltd AYCF6X 用户手册
Technical Specifications
AYC-F/G/M60 Series Installation and Programming Manual
11
2.
Technical Specifications
Electrical Characteristics
Power Supply Type
Linear (recommended)
Operating Voltage Range
5–16 VDC (when used as a controller,
provided by the secured intelligent power
provided by the secured intelligent power
supply)
Input current standby (12
VDC)
VDC)
100 mA
Input Current Max (16 VDC) 140 mA
LED Control Input
LED Control Input
Dry contact N.O.
Tamper Output
Open collector, active low, 32 mA max sink
current
Cable Distance to Host
Controller
Controller
Up to 150 m (500 ft) using an 18 AWG cable
Max. Proximity Card Read
Range*
Range*
60 mm (2.4 in.)
Proximity Card Modulation Rosslare proximity/HID Prox at 125 kHz
Proximity Card Compatibility Rosslare proximity/HID Prox cards
Card Transmit Format
(Reader)
Proximity Card Compatibility Rosslare proximity/HID Prox cards
Card Transmit Format
(Reader)
Rosslare proximity cards: Wiegand 26-Bit, or
Clock & Data
HID Prox cards: According to card type
Clock & Data
HID Prox cards: According to card type
Keypad Transmit Format
(Reader)
(Reader)
Programmable PIN code formats (see Section
LED Indicators
Two tri-colored LEDs
Communication
Data1/C1, Data0/C2–open collector, 5 V
termination
termination
* Measured using a Rosslare proximity card or equivalent. Range also
depends on electrical environment and proximity to metal.