Rosslare Enterprises Ltd AYCF6X 用户手册

下载
页码 66
Reader Operation 
22 
AYC-F/G/M60 Series Installation and Programming Manual 
If an incorrect option number is entered, the reader returns to 
Standby mode and the keypad transmission format remains 
unchanged. 
4.2.3.1
  Single Key, Wiegand 6-Bit (Rosslare Format) 
Each key press immediately sends 4 bits with 2 parity bits added – 
even parity for the first 3 bits and odd parity for the last 3 bits. 
0 = 1 1010 0 ="A" in Hexadecimal 
6 = 1 0110 0 
1 = 0 0001 0 
7 = 1 0111 1 
2 = 0 0010 0 
8 = 1 1000 1 
3 = 0 0011 1 
9 = 1 1001 0 
4 = 1 0100 1 
* = 1 1011 1 ="B" in Hexadecimal 
5 = 1 0101 0 
# = 0 1100 1 ="C" in Hexadecimal 
4.2.3.2
  Single Key, Wiegand 6-Bit Nibble and Parities 
Each key press immediately sends 4 bits with 2 parity bits added – 
even parity for the first 3 bits and odd parity for the last 3 bits. 
0 = 0 0000 1 
6 = 1 0110 0 
1 = 0 0001 0 
7 = 1 0111 1 
2 = 0 0010 0 
8 = 1 1000 1 
3 = 0 0011 1 
9 = 1 1001 0 
4 = 1 0100 1 
* = 1 1010 0 = "A" in Hexadecimal 
5 = 1 0101 0 
# = 1 1011 1 = "B" in Hexadecimal 
4.2.3.3
  Single Key, Wiegand 8-Bit Nibbles Complemented 
This options inverts the most significant bits in the message leaving 
the least 4 significant bits as BCD representation of the key. The host 
system receives an 8-bit message. 
0 = 11110000 
6 = 10010110 
1 = 11100001 
7 = 10000111 
2 = 11010010 
8 = 01111000 
3 = 11000011 
9 = 01101001 
4 = 10110100 
* = 01011010 = "A" in Hexadecimal 
5 = 10100101 
# = 01001011 = "B" in Hexadecimal