Rosslare Enterprises Ltd AYCF6X 用户手册
Reader Operation
22
AYC-F/G/M60 Series Installation and Programming Manual
If an incorrect option number is entered, the reader returns to
Standby mode and the keypad transmission format remains
unchanged.
unchanged.
4.2.3.1
Single Key, Wiegand 6-Bit (Rosslare Format)
Each key press immediately sends 4 bits with 2 parity bits added –
even parity for the first 3 bits and odd parity for the last 3 bits.
0 = 1 1010 0 ="A" in Hexadecimal
6 = 1 0110 0
1 = 0 0001 0
7 = 1 0111 1
2 = 0 0010 0
8 = 1 1000 1
3 = 0 0011 1
9 = 1 1001 0
4 = 1 0100 1
* = 1 1011 1 ="B" in Hexadecimal
5 = 1 0101 0
# = 0 1100 1 ="C" in Hexadecimal
4.2.3.2
Single Key, Wiegand 6-Bit Nibble and Parities
Each key press immediately sends 4 bits with 2 parity bits added –
even parity for the first 3 bits and odd parity for the last 3 bits.
0 = 0 0000 1
6 = 1 0110 0
1 = 0 0001 0
7 = 1 0111 1
2 = 0 0010 0
8 = 1 1000 1
3 = 0 0011 1
9 = 1 1001 0
4 = 1 0100 1
* = 1 1010 0 = "A" in Hexadecimal
5 = 1 0101 0
# = 1 1011 1 = "B" in Hexadecimal
4.2.3.3
Single Key, Wiegand 8-Bit Nibbles Complemented
This options inverts the most significant bits in the message leaving
the least 4 significant bits as BCD representation of the key. The host
the least 4 significant bits as BCD representation of the key. The host
system receives an 8-bit message.
0 = 11110000
6 = 10010110
1 = 11100001
7 = 10000111
2 = 11010010
8 = 01111000
3 = 11000011
9 = 01101001
4 = 10110100
* = 01011010 = "A" in Hexadecimal
5 = 10100101
# = 01001011 = "B" in Hexadecimal