Rosslare Enterprises Ltd AYCF6X 用户手册
Controller Operation
62
AYC-F/G/M60 Series Installation and Programming Manual
If the Programming code is valid, all memory is erased. You hear
three beeps and the controller returns to Normal mode.
If the Programming code is invalid, you hear a long beep and the
If the Programming code is invalid, you hear a long beep and the
controller returns to Normal mode without erasing the memory
contents.
contents.
5.9.17
Replacing a Lost Programming Code
The unit must be in Normal mode; otherwise, this does not
work. Make sure that the left LED is green before proceeding.
work. Make sure that the left LED is green before proceeding.
1.
Remove power from the power supply unit.
2.
Press the REX button on the power supply unit.
3.
Apply power to the unit with REX button pressed.
4.
Release the REX button.
5.
You now have 15 seconds to program a new Programming code
into the access control unit using the default code based on the
PIN code length you chose (see Table 4) before the controller
PIN code length you chose (see Table 4) before the controller
reverts to the existing code.
5.9.18
Replacing a Lost Normal/Secure Code
The unit must be in Secure mode; otherwise, this does not
work. Make sure that the left LED is red before proceeding.
work. Make sure that the left LED is red before proceeding.
1.
Remove power from the power supply unit.
2.
Press the REX button on the power supply unit.
3.
Apply power to the unit with the REX button pressed.
4.
Release the REX button.
5.
You now have 15 seconds to program a new Normal/Secure code
into the access control unit using the default code based on the
PIN code length you chose (see Table 4) before the controller
PIN code length you chose (see Table 4) before the controller
reverts to the existing code.