Rosslare Enterprises Ltd HLX24TG 用户手册

下载
页码 34
Operating the HLX-24 
HLX-24 User Manual 
11 
3.3.2
 
Arm Home 
Home arming is an arming of all perimeter sensors and detectors as defined by 
the installer. This is intended for when home or office is occupied. 
To arm the system using HOME: 
1.
  Verify that the system is ready for arming. 
2.
  Press the HOME arming key. 
3.
  Enter your user code. 
 
If the user arms the system as HOME by remote control, a squawk 
acknowledgement is produced twice in the local sounders. 
3.3.3
 
Quick Arming 
Quick arming allows arming the system without code entry. If Quick Arming is 
enabled (by the installer during setup), a long press on one of the arming 
buttons activates Quick Arming. 
3.3.4
 
Instant Arming 
If Instant Arming mode is enabled (by the installer during configuration), the 
system skips the exit delay, cancels the entry delay configured, and initiates the 
alarm, which instantly causes an alarm to go off upon violation of any zone. 
To instantly arm the system: 
1.
  Verify that the system is ready for arming. 
2.
  Press either the HOME or the AWAY arming key. 
3.
  Enter your user code. 
4.
  Press the same arming key once again. 
3.3.5
 
Forced Arming 
If Forced Arming is enabled, the system is able to arm even when zones are in 
violation (open) but not defined as bypassed. In such a case, the system arms, 
effectively bypassing the open zone. Once the open zone is closed, the system 
completes arming, adding the previously bypassed zone to the monitored 
zones. 
3.3.6
 
Exit Delay 
An exit delay enables the user to arm the system and exit the site through a 
specified door (determined as a delay zone) using a predetermined path after 
arming the system, without setting off an alarm. 
A progress annunciation of slow-rate warning beeps sound when the system is 
armed. The system counts down the last 10 seconds of the delay if the voice 
capability is configured; otherwise, the warning beeps are faster. The exit delay 
is set at 60 seconds by default. 
The user can use the Silent Exit feature to silence the audible progress 
annunciation of the exit delay.